Your browser doesn't support javascript.
loading
Incidencia de la exposición a los rayos X en cirugías de columna / Incidence of X-rays exposure in spinal surgeries
Bazán, Pedro L; Muscia, Roberto; Gomez Cano, Joaquin; Corrales Pinto, Jossy; Borri, Alvaro E; Medina, Martín; Ciccioli, Nicolás M.
Afiliação
  • Bazán, Pedro L; Hospital Interzonal General de Agudos Gral. San Martín. La Plata. AR
  • Muscia, Roberto; Sanatorio Julio Méndez. Servicio de Ortopedia y Traumatología. Ciudad Autónoma de Buenos Aires. AR
  • Gomez Cano, Joaquin; Hospital Interzonal General de Agudos Gral. San Martín. La Plata. AR
  • Corrales Pinto, Jossy; Hospital del Obrero 4. Servicio de Ortopedia y Traumatología. Oruro. BO
  • Borri, Alvaro E; Hospital Interzonal General de Agudos Gral. San Martín. La Plata. AR
  • Medina, Martín; Hospital Interzonal General de Agudos Gral. San Martín. La Plata. AR
  • Ciccioli, Nicolás M; Hospital Interzonal General de Agudos Gral. San Martín. La Plata. AR
Rev. Asoc. Argent. Ortop. Traumatol ; 84(3): 208-216, jun. 2019.
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1020335
Biblioteca responsável: AR337.1
RESUMEN

Introducción:

El control radioscópico intraoperatorio es una práctica cada vez más frecuente, que no está libre de eventos adversos para el personal de la salud.

Objetivos:

Conocer la tasa de uso de radioscopia en la cirugía vertebral, reconocer las medidas de control, evaluar la asimilación del cirujano a los elementos de protección y analizar los eventos adversos en estos profesionales. Materiales y

Métodos:

Se envió, por correo electrónico, a cirujanos espinales, una encuesta de 17 preguntas de opciones múltiples.

Resultados:

Se recibieron 55 encuestas. El 87% se dedicaba a la columna, en más del 60% de sus prácticas. El arco en C es el método más utilizado para el control final, en forma pulsátil. Solo el 31% controla el tiempo real. El delantal plomado de una pieza es el método más utilizado, pero se desconoce cuándo se debe reemplazar. La mitad utiliza más de un elemento. Siete casos de trastornos visuales, 5 patologías tiroideas, 3 dermatitis y 2 casos de infertilidad. Tres cirujanos fueron operados por nódulos tiroideos, cataratas o neoplasia.

Conclusiones:

El control radioscópico intraoperatorio es una práctica frecuente en la cirugía espinal. El delantal plomado de una pieza es el método más utilizado y, muchas veces, se lo combina, pero se desconoce cuándo se deben renovar los plomados. Uno de cada tres cirujanos presentaron las patologías evaluadas y 3, cirugías relacionadas. Así queda en evidencia la protección y el control escasos que existen en los cirujanos especialistas, acompañados de una falta de protocolización que deja a la deriva este control. Nivel de Evidencia IV
ABSTRACT

Background:

Intraoperative radiographic control (IRC) is an increasingly common practice, but it causes certain adverse events for healthcare providers.

Objectives:

To measure the use of fluoroscopy in spinal surgery, recognize control measures, evaluate assimilation of protection elements by surgeons, and analyze adverse events for spinal surgeons. Materials and

Methods:

A survey of 17 multiple-choice questions was e-mailed to spinal surgeons.

Results:

55 surveys were answered. More than 60% of surgeons were spinal surgeons. The C-arm is the most widely used machine for final control by pulsating X-rays. Real-time controls are carried out in 31% of cases. One-piece leaded aprons are the most commonly used method, but it is unknown when they should be replaced. Half of the respondents uses more than one protection element. There were seven cases of vision changes, 5 of thyroid disorders, 3 of dermatitis, and 2 of infertility. Three surgeons required surgery for thyroid nodules, cataracts or neoplasm.

Conclusions:

IRC is a common practice in spinal surgery. One-piece leaded aprons are the most commonly used method and they are often combined with other elements, but it is not known when aprons must be replaced. One in 3 surgeons suffered from the studied conditions, and there were 3 related surgeries. Lack of adequate protection and control is a reality for specialist surgeons, together with a lack of protocols, making this an unregulated issue. Level of Evidence IV
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Meta 3.9 Reduzir as mortes por produtos químicos y contaminação do ar, água e solo Problema de saúde: Exposições Ocupacionais Base de dados: BINACIS / LILACS Assunto principal: Argentina / Proteção Radiológica / Coluna Vertebral / Exposição à Radiação / Cirurgiões Ortopédicos / Doenças Profissionais Tipo de estudo: Guia de prática clínica / Estudo de incidência / Fatores de risco / Estudo de rastreamento País/Região como assunto: América do Sul / Argentina Idioma: Espanhol Revista: Rev. Asoc. Argent. Ortop. Traumatol Assunto da revista: Ortopedia Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Argentina / Bolívia Instituição/País de afiliação: Hospital Interzonal General de Agudos Gral. San Martín/AR / Hospital del Obrero 4/BO / Sanatorio Julio Méndez/AR

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Meta 3.9 Reduzir as mortes por produtos químicos y contaminação do ar, água e solo Problema de saúde: Exposições Ocupacionais Base de dados: BINACIS / LILACS Assunto principal: Argentina / Proteção Radiológica / Coluna Vertebral / Exposição à Radiação / Cirurgiões Ortopédicos / Doenças Profissionais Tipo de estudo: Guia de prática clínica / Estudo de incidência / Fatores de risco / Estudo de rastreamento País/Região como assunto: América do Sul / Argentina Idioma: Espanhol Revista: Rev. Asoc. Argent. Ortop. Traumatol Assunto da revista: Ortopedia Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Argentina / Bolívia Instituição/País de afiliação: Hospital Interzonal General de Agudos Gral. San Martín/AR / Hospital del Obrero 4/BO / Sanatorio Julio Méndez/AR
...