Your browser doesn't support javascript.
loading
Survival of short dental implants in atrophied jaw: a systematic review
Assaf, Fatimah; Siqueira-Ibelli, Guilherme; Margonar, Rogério; Santos, Pâmela Letícia; Souza-Faloni, Ana Paula de; Pereira-Queiroz, Thallita.
Afiliação
  • Assaf, Fatimah; University Center of Araraquara, UNIARA. Dental School. Implantology Post Graduation Course. Araraquara. BR
  • Siqueira-Ibelli, Guilherme; University Center of Araraquara, UNIARA. Dental School. Implantology Post Graduation Course. Araraquara. BR
  • Margonar, Rogério; University of Araraquara - UNIARA. Dental School. Program in Implantology. BR
  • Santos, Pâmela Letícia; University of Araraquara - UNIARA. Dental School. Post-graduation Program in Implantology. BR
  • Souza-Faloni, Ana Paula de; University of Araraquara - UNIARA. Dental School. Post-graduation Program in Implantology. BR
  • Pereira-Queiroz, Thallita; University of Araraquara - UNIARA. Dental School. Post-graduation Program in Implantology. BR
Int. j interdiscip. dent. (Print) ; 13(1): 44-46, abr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1114893
Biblioteca responsável: CL1.1
ABSTRACT

AIM:

Short implants are manufactured for use in atrophic regions of the jaw. Therefore, the current does not sufficiently reveal a direct correlation between the impact of implant length on implant survival. The purpose of this systematic review was to compile the evidence of short implant survival in atrophied jaws.

METHODS:

Electronic and manual literature searches were performed by two independent reviewers in several databases, including MEDLINE, EMBASE, and Cochrane Oral Health Group Trials Register, for articles up to September 2015 using the following terms in some combinations "short implant", "mandible/atrophied jaws", and "implant survival/ survival rate/ survival analysis".

RESULTS:

The 19 included studies present in average 5.5 years (range 1.0-20.0 years) follow-up and 96.1% (range 73.4-100.0 percent) survival rate of the short implants in atrophied mandibular.

CONCLUSIONS:

This systematic review found evidences regarding to safety of short implant placement in atrophied jaws although stronger evidence is essential to confirm this finding.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Implantes Dentários / Implantação Dentária Endóssea / Procedimentos Cirúrgicos Ortognáticos Tipo de estudo: Revisão sistemática Limite: Humanos Idioma: Inglês Revista: Int. j interdiscip. dent. (Print) Assunto da revista: Medicina Cl¡nica / Odontologia / Patologia Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: University Center of Araraquara, UNIARA/BR / University of Araraquara - UNIARA/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Implantes Dentários / Implantação Dentária Endóssea / Procedimentos Cirúrgicos Ortognáticos Tipo de estudo: Revisão sistemática Limite: Humanos Idioma: Inglês Revista: Int. j interdiscip. dent. (Print) Assunto da revista: Medicina Cl¡nica / Odontologia / Patologia Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: University Center of Araraquara, UNIARA/BR / University of Araraquara - UNIARA/BR
...