Your browser doesn't support javascript.
loading
Autologous blood salvage in cardiac surgery: clinical evaluation, efficacy and levels of residual heparin
Vieira, Sérgio Domingos; Perini, Fernanda da Cunha Vieira; Sousa, Luiz Carlos Bento de; Buffolo, Enio; Chaccur, Paulo; Arrais, Magaly; Jatene, Fábio Biscegli.
Afiliação
  • Vieira, Sérgio Domingos; Banco de Sangue de São Paulo. São Paulo. BR
  • Perini, Fernanda da Cunha Vieira; Banco de Sangue de São Paulo. São Paulo. BR
  • Sousa, Luiz Carlos Bento de; Hospital do Coração da Assoc. Sanatório Sírio. São Paulo. BR
  • Buffolo, Enio; Hospital do Coração da Assoc. Sanatório Sírio. São Paulo. BR
  • Chaccur, Paulo; Hospital do Coração da Assoc. Sanatório Sírio. São Paulo. BR
  • Arrais, Magaly; Hospital do Coração da Assoc. Sanatório Sírio. São Paulo. BR
  • Jatene, Fábio Biscegli; Hospital do Coração da Assoc. Sanatório Sírio. São Paulo. BR
Hematol., Transfus. Cell Ther. (Impr.) ; 43(1): 1-8, Jan.-Mar. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1154297
Biblioteca responsável: BR408.1
Localização: BR408.1
ABSTRACT
ABSTRACT

Objective:

Intraoperative blood salvage (cell saver technique) in cardiac surgery is universally used in surgical procedures with a marked risk of blood loss. The primary objectives of this study were to determine the concentration of residual heparin in the final product that is reinfused into the patient in the operating room and to evaluate the efficacy and safety of the cell saver technique.

Method:

Twelve patients undergoing elective cardiac surgery were enrolled in this study. Using the XTRA Autotransfusion System, blood samples were collected from the cardiotomy reservoir, both prior to blood processing (pre-sample) and after it, directly from the bag with processed product (post-sample). Hematocrit and hemoglobin levels, the protein, albumin and residual heparin concentrations, hemolysis index, and the platelet, erythrocyte and leukocyte counts were measured.

Results:

Hematocrit and hemoglobin levels and red blood cell counts were higher in post-processing samples, with a mean variation of 54.78%, 19.81 g/dl and 6.84 × 106/mm3, respectively (p < 0.001). The mean hematocrit of the processed bag was 63.49 g/dl (range 57.2-67.5). The residual heparin levels were ≤0.1 IU/ml in all post-treatment analyses (p = 0.003). No related adverse events were observed.

Conclusion:

The reduced residual heparin values (≤0.1 IU/ml) in processed blood found in this study are extremely important, as they are consistent with the American Association of Blood Banks guidelines, which establish target values below 0.5 IU/ml. The procedure was effective, safe and compliant with legal requirements and the available international literature.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Transfusão de Sangue Autóloga / Heparina / Recuperação de Sangue Operatório Tipo de estudo: Guia de prática clínica Limite: Adolescente / Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Hematol., Transfus. Cell Ther. (Impr.) Assunto da revista: Hematologia / TransfusÆo de Sangue Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Banco de Sangue de São Paulo/BR / Hospital do Coração da Assoc/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Transfusão de Sangue Autóloga / Heparina / Recuperação de Sangue Operatório Tipo de estudo: Guia de prática clínica Limite: Adolescente / Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Hematol., Transfus. Cell Ther. (Impr.) Assunto da revista: Hematologia / TransfusÆo de Sangue Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Banco de Sangue de São Paulo/BR / Hospital do Coração da Assoc/BR
...