Your browser doesn't support javascript.
loading
Acurácia da análise da discrepância de Bolton proposta por método manual e digital com softwares ortodônticos / ccuracy of Bolton discrepancy analysis proposed by manual and digital method with orthodontic software
Rio de Janeiro; s.n; 2022. 77 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1402410
Biblioteca responsável: BR1141.1
Localização: BR1141.1
RESUMO
objetivo desse estudo foi avaliar o desempenho diagnóstico da Análise da Discrepância de Bolton (DB) anterior e total proposta pelo programa ClinCheck®, bem como dos softwares ortodônticos Dolphin Imaging® e 3D Slicer, comparado com mensurações manuais realizados em modelos impressos tridimensionalmente. Cinquenta e cinco pares de modelos digitais da fase inicial de pacientes tratados com sistema Invisalign® (Align, San Jose, Califórnia, EUA) foram impressos tridimensionalmente por estereolitografia e usados para mensuração da DB por método manual, com paquímetro digital, por um operador previamente calibrado. Os valores da DB fornecidos pelo software de planejamento ClinCheck® foram tabulados e os arquivos da amostra em formato STL foram medidos utilizando os softwares Dolphin Imaging® e 3D Slicer. Para avaliar a confiabilidade das análises usadas como referência das comparações seguintes, o erro do método foi calculado utilizando vinte por cento da amostra, com intervalo de 2 semanas. A análise estatística foi executada no software Jamovi (versão 2.0) e um nível de significância de 5% foi adotado. Os dados em milímetros foram avaliados pelo coeficiente de correlação intraclasse (ICC), fórmula de Dahlberg, teste t pareado e método de Bland-Altman. Os resultados indicaram que os três métodos evidenciaram medidas confiáveis (ICC ≥ 0,7), sendo a DB anterior ligeiramente mais confiável. No entanto, apenas as medidas da DB anterior realizadas pelo ClinCheck e Dolphin Imaging® foram acuradas (p>0,5, sem viés de proporção). Para o DB total, todos os programas pesquisados apresentaram diferença estatisticamente significativa em relação ao método manual (p<0.001), embora essas diferenças não tenham implicação clínica relevante. Conclui-se que as ferramentas disponíveis apresentam validade para aplicação no diagnóstico e planejamento ortodôntico no que diz respeito a DB, especialmente as medidas indicadas pelo ClinCheck® e Dolphin Imaging® para região anterior do arco. (AU)
ABSTRACT
This study aimed to evaluate the diagnostic performance of the analysis of anterior and overall Bolton Discrepancy (BD) proposed by the ClinCheck® program, as well as the orthodontic software Dolphin Imaging® and 3D Slicer, compared with manual measurements performed on three-dimensionally printed models. Fifty-five pairs of early-stage digital models of patients treated with the Invisalign® system (Align, San Jose, California, USA) were three-dimensionally printed by stereolithography and used to measure BD by manual method with a digital caliper by a previously calibrated operator. DB values provided by ClinCheck® planning software were tabulated and sample files in STL format were measured using Dolphin Imaging® and 3D Slicer software. To assess the reliability of the analyzes used as a reference for the following comparisons, the method error was calculated using twenty percent of the sample, with an interval of 2 weeks. Statistical analysis was performed using the Jamovi software (version 2.0) and a significance level of 5% was adopted. Data in millimeters were evaluated using the intraclass correlation coefficient (ICC), Dahlberg formula, paired t-test, and the Bland-Altman method. The results indicated that the three methods showed reliable measurements (ICC ≥ 0.7), with the anterior BD slightly more reliable. However, only anterior BD measurements performed by ClinCheck® and Dolphin Imaging® were accurate (p>0.5, without proportion bias). For overall BD, all programs surveyed showed a statistically significant difference from the manual method (p<0.001), although these differences have no relevant clinical implications. The available tools studied are valid for application in the diagnosis and orthodontic planning concerning BD, especially the measures indicated by ClinCheck® and Dolphin Imaging® for the anterior region of the arch. (AU)
Licença
CC0 - Dedicação ao Domínio Público
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Ortodontia / Software / Diagnóstico por Computador / Impressão Tridimensional Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo prognóstico Idioma: Português Ano de publicação: 2022 Tipo de documento: Tese
Texto completo: Disponível Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Ortodontia / Software / Diagnóstico por Computador / Impressão Tridimensional Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo prognóstico Idioma: Português Ano de publicação: 2022 Tipo de documento: Tese
...