Your browser doesn't support javascript.
loading
Queratometrías por Pentacam y método de Maloney en pacientes con catarata y cirugía refractiva corneal previa / Keratometries taken with Pentacam and Maloney method in patients with cataract and previous corneal refractive surgery
Pérez Candelaria, Eneida; Cárdenas Díaz, Taimi; Ojeda Gómez, Alejandro; Rodríguez Suárez, Belkys; Veitía Rovirosa, Zucell Ana; Méndez Duque de Estrada, Ana.
Afiliação
  • Pérez Candelaria, Eneida; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cárdenas Díaz, Taimi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Ojeda Gómez, Alejandro; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Rodríguez Suárez, Belkys; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Veitía Rovirosa, Zucell Ana; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Méndez Duque de Estrada, Ana; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 29(4): 632-644, oct.-dic. 2016. tab
Artigo em Espanhol | LILACS | ID: biblio-845046
Biblioteca responsável: CU1.1
RESUMEN

Objetivo:

comparar las queratometrías obtenidas por el Pentacam y el método de Maloney en pacientes con catarata, operados previamente de cirugía refractiva corneal.

Métodos:

se realizó un estudio descriptivo, longitudinal, prospectivo y comparativo entre los valores queratométricos obtenidos mediante el método de Maloney y el Pentacam en pacientes con catarata y cirugía refractiva corneal previa. Se estudiaron 41 ojos de 31 pacientes distribuidos en dos grupos, con 23 y 18 ojos para Maloney y Pentacam respectivamente. La información de la base de datos fue procesada con el software SPSS versión 11.0 para Window. Se trabajó con un nivel de confianza del 95 por ciento y de error inferior al 0,05 por ciento.

Resultados:

en ambos grupos prevaleció el astigmatismo miópico (simple o compuesto), lo cual se encontró en 14 ojos (60,9 por ciento) del grupo 1 y 16 ojos (89 por ciento) del grupo 2. La mayoría de los ojos estudiados (37) tenían queratotomía radiada, y solo 4,3 del Grupo 1 y 1 del Grupo 2 tenían LASEK miópico. La queratometría promedio obtenida por el método de Maloney fue de 37,55 D, mientras que el valor promedio brindado por el Pentacam (EKR a 4,0 mm) fue de 39,18 D, con una diferencia promedio de 1,64 D, que fue significativa (p= 0,019).

Conclusiones:

los valores queratométricos aportados por el método de Maloney y las EKR a 4,0 mm del modo Holladay Report del Pentacam presentan diferencias significativas en pacientes con queratotomía radiada previa(AU)
ABSTRACT

Objective:

to compare the keratometries with Pentacam and with Maloney method in patients with cataract, who had previously undergone refractive corneal surgery.

Methods:

comparative, prospective, descriptive and longitudinal study of keratometric values estimated with Pentacam camera and with Maloney's method in patients with cataract and previous corneal refractive surgery. Forty one eyes were distributed into two groups; twenty three were studied by Maloney method and 18 by Pentacam. Database information was processed by was processed by version 11.0 SPSS software for Windows. The confidence interval was 95 percent and the error margin below 0.05 percent.

Results:

myopic astigmatism (simple or compound) prevailed and it was found in 14 eyes (60.9 percent) of Group 1 and in 16 eyes (89 percent) of group 2. Most of the studied eyes (37) had radiated keratotomy and just 4.3 in group 1 and one in group 2 had myopic LASEK. The average keratometry with Maloney's method was 37.55 D whereas the average value provided by the Pentacam (EKR at 4,0 mm) was 39.18 D, with a significant average difference of 1.64 D (p= 0.019).

Conclusions:

the keratometric values estimated by Maloney's method and the EKR at 4,0 mm from the Holladay Report of Pentacam show significant differences in patients with previous radiated keratotomy(AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ceratectomia Fotorrefrativa / Lâmina Limitante Anterior / Procedimentos Cirúrgicos Refrativos / Ceratite Tipo de estudo: Estudo observacional Limite: Idoso / Feminino / Humanos Idioma: Espanhol Revista: Rev. cuba. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ceratectomia Fotorrefrativa / Lâmina Limitante Anterior / Procedimentos Cirúrgicos Refrativos / Ceratite Tipo de estudo: Estudo observacional Limite: Idoso / Feminino / Humanos Idioma: Espanhol Revista: Rev. cuba. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU
...