Taxa de sobrevivência de implantes e biomateriais no levantamento do seio maxilar com pneumatização significativa: um estudo retrospectivo com 79 pacientes, durante seis meses a dez anos / Survival rate of immediate dental implants and biomaterials after large sinus lifting procedures: a retrospective study on 79 patients with a 6-month to 10-year follow-up
ImplantNewsPerio
; 2(3): 419-424, mai.-jun. 2017. ilus, tab
Artigo
em Português
| LILACS, BBO - Odontologia
| ID: biblio-847242
Biblioteca responsável:
BR510.1
RESUMO
Objetivo:
avaliar retrospectivamente a taxa de sucesso de implantes e biomateriais após o levantamento do seio maxilar. Material emétodos:
foram utilizados prontuários de pacientes tratados entre 1998 e 2014, incluídos os que possuíam rebordo maxilar com altura menor do que 5 mm. Todos os procedimentos de enxertia foram realizados com instalação de implante de forma mediata e acesso ao seio maxilar pela janela óssea lateral, colocação do biomaterial, membrana e sutura.Resultados:
foram analisados 79 pacientes, tendo sido utilizados dois biomateriais. O tempo de reavaliação variou de seis meses a dez anos. Nos dados de altura óssea radiográfica antes e depois do procedimento (70 implantes, 36 pacientes), houve um aumento médio de altura na região do seio maxilar com o Bio-Oss de 17,23 mm e com o Orthogen de 13,12 mm (p < 0,05), sendo a média geral de 15,17 mm. Na relação sobrevida do implante e enxerto utilizado (92 implantes, 43 pacientes), os valores foram de 96,8% (autógeno) e 98,3% (autógeno + biomaterial).Conclusão:
os resultados permitiram concluir que tanto os enxertos autógenos como os biomateriais são alternativas viáveis para os seios maxilares com grande pneumatização.ABSTRACT
Objective:
to retrospectively evaluate the success rate of implants and biomaterials after maxillary sinus lift. Material andmethods:
records of patients treated between 1998 and 2014 were used, including those with maxillary ridge height less than 5 mm. All grafting procedures were performed with implant placement and access to the maxillary sinus through the lateral bony window, placement of the biomaterial, membrane and suture.Results:
79 patients were analyzed and two biomaterials were used. The follow-up period ranged from six months to ten years. In the radiographic bone height data before and after the procedure (70 implants, 36 patients), there was a mean increase in height in the maxillary sinus region with the Bio-Oss of 17.23 mm and with the Orthogen of 13.12 mm (p < 0.05), the overall mean being 15.17 mm. Regarding implant and graft survival (92 implants, 43 patients), the values were 96.8% (autogenous) and 98.3% (autogenous + biomaterial).Conclusion:
both autogenous grafts and biomaterials are viable alternatives for the maxillary sinuses with great pneumatization.
Buscar no Google
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Transplante Autólogo
/
Materiais Biocompatíveis
/
Implantes Dentários
/
Estudos Retrospectivos
/
Transplante Ósseo
/
Levantamento do Assoalho do Seio Maxilar
Tipo de estudo:
Estudo de incidência
/
Estudo observacional
Limite:
Humanos
Idioma:
Português
Revista:
ImplantNewsPerio
Assunto da revista:
Odontologia
Ano de publicação:
2017
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
USP/BR
/
Unesp/BR
/
Universidade Federal de Mato Grosso do Sul (UFMS)/BR