Your browser doesn't support javascript.
loading
Novo componente de transferência para implantes. Estudo in vitro / New transfer component for dental implants. In vitro study
Nunes Filho, Djalma Pereira; Carvalho, Paulo Sérgio Perri de; Vedovatto, Eduardo.
Afiliação
  • Nunes Filho, Djalma Pereira; s.af
  • Carvalho, Paulo Sérgio Perri de; UNESP. Araçatuba. BR
  • Vedovatto, Eduardo; s.af
ProteseNews ; 4(1): 30-40, jan.-mar. 2017. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-859164
Biblioteca responsável: BR510.1
RESUMO
Os autores avaliaram, em um microscópio eletrônico de varredura (MEV), a precisão da moldagem de transferência de implantes de hexágono externo por meio de um novo modelo de transferente, comparando-o com a técnica do transferente quadrado. Foram realizadas 40 moldagens, 20 com componente de transferência quadrado (grupo-controle) e 20 com o componente de transferência implant smart transfer ­ IST (grupo-teste), a partir de um modelo acrílico padronizado com três réplicas de implantes de hexágono externo posicionados na região posterior, simulando uma condição clínica em mandíbula. Uma estrutura metálica padrão em liga de titânio foi parafusada sobre os análogos dos modelos obtidos sob torque de 10 Ncm. Foram realizadas leituras na face vestibular e na face lingual do conjunto análogo/estrutura padrão, tendo a posição central como ponto de eleição. Os resultados foram analisados estatisticamente (p-valor=0,05) e, embora tenham havido diferenças médias entre os grupos, as mesmas não foram estatisticamente significantes. Foi possível concluir que não existe diferença na precisão das moldagens de implantes realizadas com componente de transferência quadrado e o modelo implant smart transfer para prótese parcial fixa.
ABSTRACT
The authors evaluated by scanning electron microscopy (SEM), precision impression transfer of external hex implants through a new transfer model by comparing it with the technical square transfer. Fourty impressions were made; 20 with square transfer component (control) and 20 with the IST transfer component (test) from a standard acrylic model with three external hexagon implant replicas positioned in the posterior region simulating a clinical jaw condition. A titanium framework was screwed onto the implant analogs with a 10 Ncm torque. Three measurements were performed on the buccal aspect and three on the lingual surface, with the middle position as election point. The results were analyzed statistically (p=0.05), although there have been average differences between the groups, they were not statistically significant. It was concluded there was no difference in the accuracy of impression made with square transfer component and implant smart transfer model for fixed partial dentures.
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Microscopia Eletrônica de Varredura / Implantes Dentários / Técnica de Moldagem Odontológica / Materiais para Moldagem Odontológica Tipo de estudo: Estudo de avaliação Limite: Humanos Idioma: Português Revista: ProteseNews Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: UNESP/BR
Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Microscopia Eletrônica de Varredura / Implantes Dentários / Técnica de Moldagem Odontológica / Materiais para Moldagem Odontológica Tipo de estudo: Estudo de avaliação Limite: Humanos Idioma: Português Revista: ProteseNews Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: UNESP/BR
...