Your browser doesn't support javascript.
loading
Retentive force comparison between esthetic and metal clasps for removable partial denture / Comparação da força retentiva entre grampos estéticos e metálicos para prótese parcial removível
YAMAMOTO, Eron Toshio Colauto; SATO, Tabata Prado; SILVA, João Mauricio Ferraz da; BORGES, Alexandre Luiz Souto; UEMURA, Eduardo Shigueyuki.
Afiliação
  • YAMAMOTO, Eron Toshio Colauto; Universidade Nove de Julho. Dental School. Department of Prosthodontics. São Paulo. BR
  • SATO, Tabata Prado; São Paulo State University (Unesp). Institute of Science and Technology. Department of Dental Materials and Prosthodontics. São José dos Campos. BR
  • SILVA, João Mauricio Ferraz da; São Paulo State University (Unesp). Institute of Science and Technology. Department of Dental Materials and Prosthodontics. São José dos Campos. BR
  • BORGES, Alexandre Luiz Souto; São Paulo State University (Unesp). Institute of Science and Technology. Department of Dental Materials and Prosthodontics. São José dos Campos. BR
  • UEMURA, Eduardo Shigueyuki; São Paulo State University (Unesp). Institute of Science and Technology. Department of Dental Materials and Prosthodontics. São José dos Campos. BR
Braz. dent. sci ; 20(3): 87-92, 2017. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-868107
Biblioteca responsável: BR243.1
RESUMO

Objetivo:

Este estudo teve como objetivo avaliar a retenção do grampo de resina de acetato quando comparado ao grampo metálico. Material e

métodos:

Para isso, 10 grampos metálicos Co-Cr convencionais (Ackers) e 20 de resina de acetate foram confeccionados. Os grampos de resina de acetato foram constituídos por braços de oposição, suporte e retenção feitos de CoCr. Dos 20 grampos estéticos, 10 tiveram a espessura do braço de retenção diminuídos para torná-los mais estéticos. A força de retenção inicial dos espécimes foi testada em uma máquina de teste universal através de teste de tração. Depois disso, os espécimes foram submetidos a 7.000 ciclos, cada um, em uma máquina adaptada, imersos em saliva artificial, por 36 meses, simulando uso clínico de uma prótese parcial removível. Os dados foram tabulados para análise estatística da eficácia de retenção.

Resultados:

Após ciclagem, os grampos de resina de acetato de 3 mm de espessura e 2 mm de espessura perderam mais retenção do que os grampos metálicos. O tipo de material (p = 0,0000) e a ciclagem (p = 0,0039) mostraram um efeito significativo, mas a interação material / ciclagem (p = 0,1436) não.

Conclusões:

Portanto, os grampos estéticos apresentaram força de retenção inferior à dos grampus metálicos. No entanto, os grampos estéticos podem ser utilizados em casos clínicos que requerem retenção mínima. (AU)
ABSTRACT

Objective:

This study aimed to evaluate the retention of acetate resin clasp as when compared to metal clasp. Material and

methods:

For this purpose, we constructed 10 conventional Co-Cr metal clasps (Ackers) and 20 acetate resin clasps. The acetate resin clasps had the opposition, support and retaining arms made of Co-Cr. Of the 20 esthetic clasps, 10 had the thickness of the retention arm decreased to make it more esthetic. The initial retentive force of the specimens was tested in a universal testing machine through tensile test. After that, the specimens were subjected to 7,000 cycles, each one, in an adapted machine, immersed into artificial saliva, for 36 months of simulated clinical use of a removable partial denture. Data were tabulated for statistical analysis of the retention effectiveness.

Results:

After cycling, 3-mm-thick and 2-mmthick acetate resin clasps lost more retention than metal clasps. The material type (p=0.0000) and cycling (p=0.0039) showed a significant effect, but the material/cycling interaction (p=0.1436) did not.

Conclusions:

Therefore, esthetic clasps presented retention force lower than that of metal clasps. Notwithstanding, the esthetic clasps can be used in clinical cases requiring minimum retention. (AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Grampos Dentários / Prótese Parcial Removível Idioma: Inglês Revista: Braz. dent. sci Assunto da revista: Odontologia / Sa£de Bucal Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Paulo State University (Unesp)/BR / Universidade Nove de Julho/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Grampos Dentários / Prótese Parcial Removível Idioma: Inglês Revista: Braz. dent. sci Assunto da revista: Odontologia / Sa£de Bucal Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Paulo State University (Unesp)/BR / Universidade Nove de Julho/BR
...