Estudo da ação do EDTA sobre a camada residual no tempo de 1 e 3 minutos / Action of 1- and 3- minute EDTA applications on the smear layer
Pesqui. bras. odontopediatria clín. integr
; 9(3): 367-372, set.-dez. 2009.
Artigo
em Português
| LILACS, BBO - Odontologia
| ID: biblio-873921
Biblioteca responsável:
BR1264.1
RESUMO
Objetivo:
Analisar, in vitro, através da Microscopia Eletrônica de Varredura, o efeito do EDTA nas concentrações de 3%, 5%, 10% e 17%, na remoção da camada residual e na desobstrução dos túbulos dentinários, nos tempos de 1 e 3 minutos.Método:
Da amostra constituída de 80 dentes, foram selecionadas, randomicamente, oito unidades para compor o grupo controle negativo (GC1) e 8 para constituírem o grupo controle positivo (GC2). Os 64 restantes compuseram os oito Grupos Experimentais (GExp.). Após a instrumentação do canal radicular foi realizada a irrigação final com as soluções de EDTA em teste, sendo considerados os tempos de 1 minuto e 3 minutos de permanência deste em contato com a superfície dentinária.Resultados:
A análise das fotomicrografias com magnitude de 2000X, revelam que as soluções de EDTA a 10% e 17% foram as mais eficazes, independente dos tempos de aplicação prédeterminados.Conclusão:
A respeito da remoção da camada residual e da desobstrução dos túbulos dentinários do canal radicular, que a eficácia do EDTA não se altera com o aumento do tempo de aplicação nos tempos de 1 minuto ou 3 minutos.ABSTRACT
Objective:
To analyze, in vitro, by scanning electron microscopy (SEM), the effect of EDTA at concentrations of 3%, 5%, 10% and 17% for 1 and 3 minutes, on the removal of the smear layer and opening of dentinal tubules.Method:
Eighty teeth were randomly assigned to groups as follows 8 specimens were allocated to the negative control group (CG1), 8 to the positive control group (GC2), and the other 64 were distributed to 8 experimental groups (ExpG). After root canal instrumentation, final irrigation was done with the EDTA solutions, which were left in contact with the dentin surfaces for 1 and 3 minutes.Results:
The analysis of the SEM micrographs at ×2,000 magnification revealed that 10% and 17% EDTA solutions were the most effective, regardless of the application time.Conclusion:
Regarding the smear layer removal and dentinal tubule opening, the efficacy of EDTA is not altered with the increase of the application time from 1 to 3 minutes
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Microscopia Eletrônica de Varredura
/
Quelantes
/
Camada de Esfregaço
/
Ácido Edético
Tipo de estudo:
Ensaio clínico controlado
Limite:
Humanos
Idioma:
Português
Revista:
Pesqui. bras. odontopediatria clín. integr
Assunto da revista:
Odontologia
Ano de publicação:
2009
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Universidade Federal da Bahia/BR