Análise comparativa in vivo do potencial de osseointegração entre três marcas de implantes líderes no mercado europeu / In vivo comparative analysis of the osseointegration potential among three leading implant brands in the European market
ImplantNewsPerio
; 3(2): 274-282, mar.-abr. 2018. ilus
Artigo
em Português
| LILACS, BBO - Odontologia
| ID: biblio-883513
Biblioteca responsável:
BR510.1
RESUMO
Objetivos:
avaliar in vivo (histomorfometricamente) o potencial de osseointegração de três marcas comerciais de implantes consideradas como de primeira linha no mercado mundial. Material emétodos:
seis coelhos New Zealand, de mesmo peso e idade, receberam 24 implantes de diâmetros similares e comprimentos iguais, de três marcas com tratamentos de superfície variados G1 (Nobel Biocare, Nobel Replace), G2 (MIS, V3) e G3 (Straumann, Bone Level). Os implantes foram colocados nas metáfises proximais e distais seguindo os protocolos de osteotomia. Após anestesia e sacrífi co dos animais, os implantes foram retirados 45 dias depois para análise histomorfométrica. Ainda, um implante de cada marca foi submetido à análise por MEV (Philips XL30) com diferentes aumentos, sendo as imagens obtidas no modo BSEs. A porcentagem de contato osso-implante entre os grupos foi analisada pelo teste Anova (α=0,05).Resultados:
os três modelos de tratamento superficial produziram alta osteocondutividade e boa formação óssea, não havendo diferença entre os valores BIC (p=0,94).Conclusão:
as três superfícies testadas apresentaram um grau de osseointegração muito similar.ABSTRACT
Objectives:
to evaluate by histomorphometrical methods (in vivo) the osseointegration potential of three different implant brands in the world market. Material andmethods:
six New Zealand rabbits of similar weight and age received 24 dental implants of similar diameters and same length, with three different implant surfaces G1 (Nobel Biocare, Nobel Replace), G2 (MIS, V3), e G3 (Straumann, Bone Level). The implants were installed at the proximal mesial and distal surfaces according the recommend osteotomies. After anesthesia and sacrifice, the implants were retrieved 45 days later for histomorphometrical analysis. Also, one implant from each company was evaluated under SEM BSE mode. The BIC percentage among groups was compared by statistical analysis (One-way ANOVA, 5% level of significance).Results:
all three different implant surfaces provided high osteoconductivity and good bone formation, with no significant differences (p=0.94).Conclusion:
similar osseointegration patterns were verified among the three tested implant brands.
Buscar no Google
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Propriedades de Superfície
/
Microscopia Eletrônica de Varredura
/
Implantes Dentários
/
Análise de Variância
/
Osseointegração
Tipo de estudo:
Estudo de avaliação
/
Guia de prática clínica
Limite:
Animais
Idioma:
Português
Revista:
ImplantNewsPerio
Assunto da revista:
Odontologia
Ano de publicação:
2018
Tipo de documento:
Artigo
País de afiliação:
Brasil
/
Portugal
/
Espanha
Instituição/País de afiliação:
Biotecnos Research Center/BR
/
Clínica privada/PT
/
PUC/BR
/
Universidade Católica San Antonio de Murcia (Ucam)/ES