Posicionamento de sonda enteral em neonatos segundo técnica modificada de mensuração / Enteral tube placement in newborns according to the modified measurement technique
Acta Paul. Enferm. (Online)
; 30(6): 590-597, Nov.-Dez. 2017. tab, graf
Artigo
em Português
| BDENF - Enfermagem, LILACS
| ID: biblio-885914
Biblioteca responsável:
BR1.2
RESUMO
Resumo Objetivo:
Avaliar a efetividade da mensuração de sonda enteral pela técnica modificada, nariz - orelha - apêndice xifoide, com desconto dos orifícios distais da sonda, para posicionamento na câmara gástrica de neonatos.Métodos:
Estudo prospectivo, desenvolvido em unidade neonatal de um hospital de ensino do município de São Paulo, a partir da análise radiográfica de 60 radiografias de 28 neonatos em uso de sonda enteral mensurada pela técnica modificada, submetidos à radiografia toracoabdominal.Resultados:
O índice de posicionamento correto, de acordo com a análise por posições, foi de 68,3% e 71,7%, segundo os avaliadores 1 e 2, respectivamente, enquanto na análise por vértebras, 95% das sondas estavam adequadamente locadas na câmara gástrica. Ocorreu associação estatisticamente significante entre estatura e localização da sonda enteral, segundo o avaliador 2.Conclusão:
A técnica de mensuração avaliada apresenta risco para posicionamento inadequado da sonda enteral utilizada em neonatos, devendo ser desencorajada sua aplicação na prática clínica.ABSTRACT
Abstract Objective:
To evaluate the effectiveness of the enteral tube measurement using the modified nose - ear - xiphoid (NEX) technique by disregarding the tube distal orifices for placement in newborns' neonatal gastric cavity.Methods:
A prospective study conducted in a neonatal unit of a teaching hospital in the city of São Paulo, based on the radiographic analysis of 60 radiographs of 28 newborns using enteral tubes measured by the modified technique, and who had thoracoabdominal radiography.Results:
The correct placement index according to analysis by position was 68.3% and 71.7%, according to evaluators 1 and 2, respectively. In the analysis by vertebrae, 95% of tubes were properly placed in the gastric cavity. There was a statistically significant association between height and location of the enteral tube according to evaluator 2.Conclusion:
The evaluated measurement technique presents a risk for inadequate enteral tube placement in newborns, and its application in clinical practice should not be encouraged.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
BDENF - Enfermagem
/
LILACS
Assunto principal:
Nutrição Enteral
/
Enfermagem Neonatal
Tipo de estudo:
Estudo observacional
/
Fatores de risco
Limite:
Feminino
/
Humanos
/
Masculino
/
Recém-Nascido
Idioma:
Português
Revista:
Acta Paul. Enferm. (Online)
Assunto da revista:
Enfermagem
Ano de publicação:
2017
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Universidade Federal de São Paulo/BR