Your browser doesn't support javascript.
loading
Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
Figuerôa, Rosana Marques Silva; Conterno, Bruna; Arrais, César Augusto Galvão; Sugio, Carolina Yoshi Campos; Urban, Vanessa Migliorini; Neppelenbroek, Karin Hermana.
Afiliação
  • Figuerôa, Rosana Marques Silva; Universidade Estadual de Ponta Grossa. Departamento de Odontologia. Ponta Grossa. BR
  • Conterno, Bruna; Universidade Estadual de Ponta Grossa. Departamento de Odontologia. Ponta Grossa. BR
  • Arrais, César Augusto Galvão; Universidade Estadual de Ponta Grossa. Departamento de Odontologia. Ponta Grossa. BR
  • Sugio, Carolina Yoshi Campos; Universidade Estadual de Ponta Grossa. Departamento de Odontologia. Ponta Grossa. BR
  • Urban, Vanessa Migliorini; Universidade Estadual de Ponta Grossa. Departamento de Odontologia. Ponta Grossa. BR
  • Neppelenbroek, Karin Hermana; Universidade Estadual de Ponta Grossa. Departamento de Odontologia. Ponta Grossa. BR
J. appl. oral sci ; 26: e20170383, 2018. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893710
Biblioteca responsável: BR1.1
ABSTRACT
Abstract The proper selection of polymerization cycle is important to prevent overheating of the monomer that could cause degradation, porosity and, consequently, deleterious effects on the denture base properties. Objective This study evaluated the porosity, water sorption and solubility of acrylic resins (Vipi Cril-VC and Vipi Wave-VW) after conventional or microwave polymerization cycles. Material and Methods Specimens (n = 10) were made and cured 1-WB = 65°C during 90 min + boiling during 90 min (VC cycle - control group); 2-M25 = 10 min at 270 W + 5 min at 0 W + 10 min at 360 W (VW cycle); 3-M3 = 3 min at 550 W; and 4-M5 = 5 min at 650 W. Afterward, they were polished and dried in a dessicator until a constant mass was reached. Specimens were then immersed in distilled water at 37°C and weighed regularly until a constant mass was achieved. For porosity, an additional weight was made with the specimen immediately immersed in distilled water. For water sorption and solubility, the specimens were dried again until equilibrium was reached. Data were submitted to 2 way-ANOVA and Tukey HSD (α=0.05). Results Porosity mean values below 1.52% with no significant difference among groups for both materials were observed. Resins showed water sorption and solubility values without a significant difference. However, there was a significant difference among groups for these both properties (P<0.013). The highest sorption (2.43%) and solubility (0.13%) values were obtained for WB and M3, respectively. Conclusions The conventional acrylic resin could be polymerized in a microwave since both the materials showed similar performance in the evaluated properties. Shorter microwave cycles could be used for both the materials without any detectable increase in volume porosity.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Resinas Acrílicas / Água / Bases de Dentadura / Polimerização Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Ponta Grossa/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Resinas Acrílicas / Água / Bases de Dentadura / Polimerização Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Ponta Grossa/BR
...