Your browser doesn't support javascript.
loading
Propagación eléctrica en los mecanismos de torsión y succión en un corazón de tres tiempos / Electrical Propagation in the Mechanisms of Twist and Suction in a Three-phase Heart
Trainini, Jorge C.; Elencwajg, Benjamín; López Cabanillas, Néstor; Herreros, Jesús; Lago, Noemí; Lowenstein, Jorge.
Afiliação
  • Trainini, Jorge C.; Sociedad Argentina de Cardiología.
  • Elencwajg, Benjamín; Hospital Interzonal General de Agudos Presidente Perón. Avellaneda. AR
  • López Cabanillas, Néstor; Sociedad Argentina de Cardiología.
  • Herreros, Jesús; Universidad Católica San Antonio (UCAM). Murcia. ES
  • Lago, Noemí; Sociedad Argentina de Cardiología.
  • Lowenstein, Jorge; Sociedad Argentina de Cardiología.
Rev. argent. cardiol ; 83(5): 420-428, oct. 2015. ilus, graf
Artigo em Espanhol | LILACS | ID: biblio-957655
Biblioteca responsável: AR1.2
RESUMEN

Introducción:

La hipótesis de Torrent Guasp plantea que los ventrículos están conformados por una banda muscular continua que nace a nivel de la válvula pulmonar y se extiende hasta la raíz aórtica delimitando las dos cavidades ventriculares. Esta anatomía brindaría la interpretación para dos aspectos fundamentales de la dinámica ventricular izquierda el mecanismo de torsión y el llenado diastólico rápido por efecto de succión.

Objetivos:

Investigar la activación eléctrica de las bandeletas endocárdica y epicárdica para comprender la torsión ventricular, el mecanismo de succión activa en la fase isovolumétrica diastólica y el significado del volumen residual. Material y

métodos:

La investigación se realizó mediante un mapeo electroanatómico tridimensional en cinco pacientes. Al ser la bandeleta descendente endocárdica y la ascendente epicárdica, se utilizaron dos vías de abordaje por punción.

Resultados:

El mapeo tridimensional endoepicárdico demuestra una activación eléctrica de la zona de la lazada apexiana concordante con la contracción sincrónica de las bandeletas descendente y ascendente. La activación simultánea y contrapuesta de la bandeleta ascendente con punto de partida de su activación radial desde la bandeleta descendente, en la zona de entrecruzamiento de ambas, es coherente con la torsión ventricular. La activación tardía de la bandeleta ascendente se compatibiliza con la persistencia de su contracción durante el período inicial de la fase isovolumétrica diastólica (base del mecanismo de succión); se produce sin necesidad de postular activaciones eléctricas posteriores al QRS.

Conclusiones:

Este trabajo explica el proceso de la torsión ventricular y el mecanismo de succión. Comprueba que la activación de la bandeleta ascendente completa el QRS anulando el concepto tradicional de relajación pasiva en la fase isovolumétrica diastólica.
ABSTRACT

Background:

The hypothesis of Torrent Guasp considers that the ventricular myocardium consists of a continuous muscular band that begins at the level of the pulmonary valve and ends at the level of the aortic root, limiting both ventricular chambers. This anatomy would provide the interpretation for two fundamental aspects of left ventricular dynamics the mechanism of left ventricular twist and rapid diastolic filling due to the suction effect.

Objectives:

The aim of this study was to investigate the electrical activation of the endocardial and epicardial bands to understand ventricular twist, the mechanism of active suction during the diastolic isovolumic phase and the significance of the residual volume.

Methods:

Five patients underwent three-dimensional electroanatomic mapping. As the descending band is endocardial and the ascending band is epicardial, two sites of puncture were used.

Results:

Three-dimensional endo-epicardial mapping demonstrates an electrical activation sequence in the area of the apex loop in agreement with the synchronic contraction of the descending and ascending band segments. The simultaneous and opposing radial activation of the ascending band segment, starting in the descending band segment, in the area in which both band segments intertwine, is consistent with the mechanism of ventricular twist. The late activation of the ascending band segment is consistent with its persistent contraction during the initial period of the isovolumic diastolic phase (the basis of the suction mechanism), and takes place without need of postulating further electrical activations after the QRS complex.

Conclusions:

This study explains the process of ventricular twist and the suction mechanism, and demonstrates that the activation of the ascending band segment completes the QRS, ruling out the traditional concept of passive relaxation during the diastolic isovolumic phase.

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Espanhol Revista: Rev. argent. cardiol Assunto da revista: Cardiologia / Doen‡as Cardiovasculares Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Argentina / Espanha Instituição/País de afiliação: Hospital Interzonal General de Agudos Presidente Perón/AR / Universidad Católica San Antonio (UCAM)/ES
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Espanhol Revista: Rev. argent. cardiol Assunto da revista: Cardiologia / Doen‡as Cardiovasculares Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Argentina / Espanha Instituição/País de afiliação: Hospital Interzonal General de Agudos Presidente Perón/AR / Universidad Católica San Antonio (UCAM)/ES
...