Implante de audífono de conducción ósea osteointegrado: experiencia del Hospital Universitario de la Samaritana, Bogotá, D. C. / Bone anchored hearing aid: the Hospital Universitario de la Samaritana's experience, Bogotá, D. C.
Acta otorrinolaringol. cir. cabeza cuello
; 45(1): 28-35, 20170000. tab, graf
Artigo
em Espanhol
| LILACS, COLNAL
| ID: biblio-969203
Biblioteca responsável:
CO361.9
RESUMEN
Objetivo:
Describir y comparar los resultados audiológicos pre y postquirúrgicos de los pacientes que fueron sometidos a implante de conducción ósea osteointegrado en el Hospital Universitario de la Samaritana, Bogotá D.C.Diseño:
Estudio tipo Cohorte descriptiva.Métodos:
Se evaluaron los resultados audiológicos pre y postquirúrgicos de 36 pacientes sometidos a Implante de audífono de conducción ósea osteointegrado.Resultados:
Se observó una disminución estadísticamente significativa entre el valor de PTA pre y postquirúrgico (Diferencia = 36.94 dB; IC95% 35.2 a 38.7; p<0.001) Mejoría en la brecha Ósea Aérea con una diferencia entre el valor previo y posterior a la intervención de 35.93 dB (IC95% 33.23 a 38.63; p<0.001). La diferencia entre el porcentaje de discriminación verbal antes y después del procedimiento quirúrgico fue de 6.67% (IC95% 1.41 a 11.92; p=0.008), con una reducción en los niveles de intensidad de sonido en la discriminación que fue de 32.26 dB (IC95% 29.21 a 35.32; p<0.001).Conclusión:
Los resultados audiológicos esperados en pacientes con hipoacusia conductiva, mixta o neurosensorial unilateral que fueron sometidos a implante de audífono de conducción ósea osteointegrado muestran que el sistema ofrece un alto porcentaje de éxito y bajas tasas de complicaciones.ABSTRACT
Objective:
To describe and compare pre and postoperative audiological results in patients who received a bone conduction hearing aid implant and the Hospital Universitario de la Samaritana, Bogotá D.C.Design:
A descriptive cohort study.Methods:
A descriptive cohort study was conducted. We evaluated audiological results before and after the bone conduction hearing aid implant procedure in 36 patients.Results:
A statistically significant decrease in the PTA value was observed after the implant procedure (difference= 36.94 dB; 95CI% 35.2 - 38.7; p<0.001) The bone-air gap also presented improvement after the intervention with a decrease of 35.93 dB (95%CI 33.23 - 38.63; p<0.001). The difference in verbal discrimination percentage after the surgical procedure was 6.67% (95%CI 1.41 - 11.92; p=0.008), with a decrease in sound intensity discrimination levels of 32.26 db (95%CI 29.21 - 35.32; p<0.001).Conclusion:
The audiological results in patients with conductive, mixed or unilateral sensorineural hearing loss that received a bone conduction hearing aid implant show that this intervention offers a high success rate and low postoperative complications.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
COLNAL
/
LILACS
Assunto principal:
Perda Auditiva
Tipo de estudo:
Estudo observacional
Limite:
Humanos
Idioma:
Espanhol
Revista:
Acta otorrinolaringol. cir. cabeza cuello
Assunto da revista:
Lesäes do Pescoo
/
Otolaringologia
/
Otorrinolaringopatias
/
Traumatismos Craniocerebrais
Ano de publicação:
2017
Tipo de documento:
Artigo
País de afiliação:
Colômbia
Instituição/País de afiliação:
Universidad del Rosario Hospital Universitario de la Samaritana/CO
/
Universidad del Rosario/CO
/
Universidad del Rosario, Hospital Universitario de la Samaritana/CO