Acoustic Voice Quality Index - AVQI para o português brasileiro: análise de diferentes materiais de fala / Acoustic Voice Quality Index - AVQI for brazilian portuguese speakers: analysis of different speech material
Englert, Marina; Lima, Livia; Constantini, Ana Carolina; Latoszek, Ben Barsties V; Maryn, Youri; Behlau, Mara.
Afiliação
  • Englert, Marina; Universidade Federal de São Paulo. São Paulo. BR
  • Lima, Livia; Centro de Estudos da Voz. São Paulo. BR
  • Constantini, Ana Carolina; Centro de Estudos da Voz. São Paulo. BR
  • Latoszek, Ben Barsties V; University of Antwerp. Antwerp. BE
  • Maryn, Youri; University of Antwerp. Antwerp. BE
  • Behlau, Mara; Universidade Federal de São Paulo. São Paulo. BR
CoDAS ; 31(1): e20180082, 2019. tab
Artigo em Português | LILACS | ID: biblio-984248
Biblioteca responsável: BR1.1
RESUMO
RESUMO Objetivo Verificar a melhor amostra de fala para validação do AVQI para o português-brasileiro; identificar o contexto de fala com melhor correlação perceptivo-acústica e que possui maior acurácia diagnóstica com o AVQI. Método Gravações de 50 sujeitos (disfônicos e vocalmente saudáveis), incluindo vogal/a/; meses do ano; números (1 a 20) e repetição das frases do CAPE-V. As amostras de fala foram editadas para conter três diferentes durações mais vogal D1-fala completa; D2-fala com 3s de segmentos sonoros; D3-fala com ponto de corte pré-determinado. Três avaliadores realizaram a análise perceptivoauditiva (APA) das amostras combinadas em 3 contextos seguidos da vogal e deram um único escore do desvio vocal (G0 a 3). Verificou-se qual estímulo de fala possuía melhor correlação perceptivo-acústica considerando o Gmédio; analisou-se qual estímulo possuía melhor acurácia diagnóstica considerando como presença ou ausência G<0,5 e G<0,68. Resultados A correlação perceptivo-acústica variou de r = 0,482 a r = 0,634 (Correlação de Spearman); números apresentou os valores mais elevados. O AVQI foi altamente específico e pouco sensível. Considerando G<0,5, a melhor sensibilidade e valor da curva ROC foi para frases em D3 (0,578;0,72). Considerando G<0,68, houve boa acurácia diagnóstica para números de 1 a 10 e maior sensibilidade para números de 1 a 20. Conclusão Melhor correlação perceptivo-acústica foi para números, 1 a 10. As frases do CAPE-V produziram melhor acurácia diagnóstica com G<0,5, números apresentou elevada acurácia diagnóstica com G<0,68. Números é bastante usual na clínica brasileira, logo, sugere-se seu uso para validação e análises do AVQI.
ABSTRACT
ABSTRACT Purpose This study aimed to verify the best speech material for the AVQI for Brazilian Portuguese language and identify the best validity results between the auditory perceptual judgment (APJ) and the AVQI score on different speech materials. Methods We recorded voice samples of 50 individuals (dysphonic and vocally healthy) of several continuous speech (cs) variants (i.e., months of the year, numbers 1 to 20, and CAPE-V sentences) and attached the vowel /a/ in each case. The recorded samples were edited to three different durations of cs variants plus vowel D1-total speech material; D2-customized speech material without voiceless parts; D3-pre-defined cut-off point speech material. These samples were submitted to three voice experts who judged the overall voice quality; and the AVQI analysis. AVQI's precision and concurrent validity were evaluated considering a Gmean threshold of G<0.5 and G<0.68. Results The concurrent validity of AVQI and APJ ranged from r = 0.482 to r = 0.634. Numbers presented higher values for all durations. For G<0.5, the best sensitivity and area under the ROC curve was for CAPE-V sentences at D3 (57.8%; 72%). For G<0.68, numbers 1 to 10 had the best diagnostic accuracy and numbers 1 to 20 had the best sensitivity. Conclusion Numbers from 1 to 10 had the best correlation results between APJ and AVQI. For G<0.5, sentences had the best diagnostic accuracy; while for G<0.68, numbers had the best diagnostic accuracy. Numbers are commonly used in the Brazilian clinic routine. According to the validity results and daily clinical practice in Brazil, we suggest the use of numbers as cs for concatenated voice samples of voice quality assessments.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Acústica da Fala / Medida da Produção da Fala / Qualidade da Voz / Disfonia Tipo de estudo: Estudo de avaliação / Estudo prognóstico Limite: Adolescente / Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: CoDAS Assunto da revista: Audiologia / Patologia da Fala e Linguagem Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Bélgica / Brasil Instituição/País de afiliação: Centro de Estudos da Voz/BR / Universidade Federal de São Paulo/BR / University of Antwerp/BE

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Acústica da Fala / Medida da Produção da Fala / Qualidade da Voz / Disfonia Tipo de estudo: Estudo de avaliação / Estudo prognóstico Limite: Adolescente / Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: CoDAS Assunto da revista: Audiologia / Patologia da Fala e Linguagem Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Bélgica / Brasil Instituição/País de afiliação: Centro de Estudos da Voz/BR / Universidade Federal de São Paulo/BR / University of Antwerp/BE
...