Estimación de la edad cardiovascular a partir de tacogramas de 2 minutos de duración mediante Análisis de Cuantificación de Recurrencias / Estimation of cardiovascular age from 2 minute tachograms via Recurrence Quantification Analysis
Rev. cuba. inform. méd
; 8(2)jul.-dic. 2016.
Artigo
em Espanhol
| CUMED
| ID: cum-65641
Biblioteca responsável:
CU1.1
Localização: CU1.1
RESUMEN
Se han reportado diferentes intentos de estimar la edad cardiovascular a partir de señales electrofisiológicas. Las propuestas publicadas presentan inconvenientes para su aplicación en la práctica clínica. Nos hemos propuesto estimar la edad cardiovascular a partir de tacogramas de 2 minutos de duración utilizando una medida no lineal (logaritmo del porcentaje de determinismo, log (DET)), obtenido a partir del Anßlisis de Cuantificación de Recurrencias. En una muestra de 62 sujetos presuntamente sanos con edades entre 9 y 79 años se obtuvo una excelente correlación entre edad y log (DET) ) r = 0.7981, comparable a los mejores valores reportados en la literatura utilizando técnicas más costosas. A partir de esos resultados se propone una vía para estimar los valores normativos para una población presuntamente sana. Se concluye que a partir de tacogramas de dos minutos de duración es posible obtener un buen estimador de la edad cardiovascular. El Análisis de Cuantificación de Recurrencias es una vía apropiada para estimar la edad cardiovascular, y la pérdida del porcentaje de determinismo con la edad posiblemente refleje una mayor contribución de los componentes estocasticos a la regulación del ritmo cardiaco en ancianos(AU)
ABSTRACT
Various attempts have been reported to estimate the cardiovascular age from different electrophysiological signals. Proposals published are hampered by drawbacks for application in clinical practice. We have proposed to estimate cardiovascular age from two- minutes tachograms using a non-linear measure (logarithm of the percentage of determinism, log (DET)) obtained from Recurrence Quantification Analysis. In a sample of 62 allegedly healthy subjects,9 to 79 years an excellent correlation between age and log (DET)) r = 0.7981 - comparable to the best values reported in the literature using more expensive techniques- was obtained. From these results the way is proposed to estimate the normative values for a presumably healthy population. It is concluded that from two-minutes tachograms it is possible to obtain a good estimate of the cardiovascular age. Recurrence Quantification Analysis of is an appropriate way to estimate cardiovascular age, and reduction in the percentage of determinism with age may reflect a greater contribution of stochastic regulation of heart rate components in the elderly subject(AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Cuba
Base de dados:
CUMED
Assunto principal:
Técnicas Eletrofisiológicas Cardíacas
/
Frequência Cardíaca
Limite:
Humanos
Idioma:
Espanhol
Revista:
Rev. cuba. inform. méd
Ano de publicação:
2016
Tipo de documento:
Artigo
Instituição/País de afiliação:
Facultad de Ciencias Médicas Diez de Octubre/Cuba