Cirugía histeroscópica en consulta con tecnología Versapoint®. Características clínicas y resultados / Operative office hysteroscopy using Versapoint® technology. Clinical characteristics and results
Rodríguez-Oliver, A. J; Fernández-Parra, J; Carrillo, M. P; Parrilla, F; Montoya, F.
Afiliação
  • Rodríguez-Oliver, A. J; Hospital Universitario Virgen de las Nieves. Granada. España
  • Fernández-Parra, J; Hospital Universitario Virgen de las Nieves. Granada. España
  • Carrillo, M. P; Hospital Universitario Virgen de las Nieves. Granada. España
  • Parrilla, F; Hospital Universitario Virgen de las Nieves. Granada. España
  • Montoya, F; Hospital Universitario Virgen de las Nieves. Granada. España
Prog. obstet. ginecol. (Ed. impr.) ; 48(8): 388-391, ago. 2005. tab
Artigo em Es | IBECS | ID: ibc-039138
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN

Objetivo:

Valorar la utilidad de la cirugía histeroscópica en consulta con el empleo de la tecnología bipolar tipo Versapoint®. Se analizan las peculiaridades, los resultados y la tolerancia. Material y

métodos:

Estudio descriptivo de 519 técnicas quirúrgicas realizadas mediante histeroscopia en consulta con tecnología Versapoint® (454 con histeroscopio rígido de 5,5 mm y 65 con histeroscopio semirrígido tipo Versascope®).

Resultados:

La duración media de la técnica fue de 7,7 min. El procedimiento más frecuente fue la polipectomía. Sólo refirieron dolor significativo y/o síndrome vagal algo menos del 2% de las pacientes.

Conclusiones:

La tecnología Versapoint® facilita la cirugía histeroscópica en consulta, y deja para el resectoscopio casos muy seleccionados. La tolerancia por parte de la paciente es muy buena
ABSTRACT

Objective:

To evaluate the utility of operative office hysteroscopy with the use of the Versapoint® bipolar electrosurgical system. We analyzed clinical characteristics, results and patient acceptability. Material and

methods:

We performed a descriptive study of 519 operative hysteroscopies, using an office hysteroscopic procedure with Versapoint® technology; 454 with a 5.5 mm rigid hysteroscope and 65 with a semirigid microhysteroscope (Versascope®).

Results:

The mean operating time was 7.7 min. The most common procedure was polypectomy. Severe pain and/or vagal reflex occurred in less than 2% of the patients.

Conclusions:

The Versapoint® bipolar technology facilitates operative office hysteroscopy and allows resectoscopy to be reserved for the treatment of special cases. Patient acceptability is high
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doenças Uterinas / Histeroscopia / Procedimentos Cirúrgicos Ambulatórios Limite: Feminino / Humanos Idioma: Espanhol Revista: Prog. obstet. ginecol. (Ed. impr.) Ano de publicação: 2005 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen de las Nieves/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doenças Uterinas / Histeroscopia / Procedimentos Cirúrgicos Ambulatórios Limite: Feminino / Humanos Idioma: Espanhol Revista: Prog. obstet. ginecol. (Ed. impr.) Ano de publicação: 2005 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen de las Nieves/España
...