Your browser doesn't support javascript.
loading
La frecuencia cardiaca en fetos con circular de cordón / Heart rate in fetuses with coiling of funis
Romero Salinas, G; Viveros Alcaraz, M; Gil Yoguez , J; Torres Cosme, M; Bobadilla Lugo, R. A; Gutiérrez Cárdenas, M. E; Shea McQuade, M; Nava Madrigal, A.
Afiliação
  • Romero Salinas, G; Secretaría de Salud del Dep del DF. Hospital Materno Infantil Inguarán. Consulta Externa. México D.F. México
  • Viveros Alcaraz, M; Secretaría de Salud del Dep del DF. Hospital Materno Infantil Inguarán. Consulta Externa. México D.F. México
  • Gil Yoguez , J; Secretaría de Salud del Dep del DF. Hospital Materno Infantil Inguarán. Consulta Externa. México D.F. México
  • Torres Cosme, M; Instituto Politécnico Nacional. Escuela Superior de Medicina. México D.F. México
  • Bobadilla Lugo, R. A; Instituto Politécnico Nacional. Escuela Superior de Medicina. México D.F. México
  • Gutiérrez Cárdenas, M. E; Universidad Autónoma Metropolitana. Unidad Xochimilco. C.B.S. México D.F. México
  • Shea McQuade, M; Universidad Autónoma Metropolitana. Unidad Xochimilco. C.B.S. México D.F. México
  • Nava Madrigal, A; Universidad Autónoma Metropolitana. Unidad Xochimilco. C.B.S. México D.F. México
Clín. investig. ginecol. obstet. (Ed. impr.) ; 40(5): 207-212, sept.-oct. 2013. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-115864
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Se determinaron los valores de la frecuencia cardiaca y la incidencia de dips tipos i y ii en los fetos con circular de cordón. Diseño del estudio La muestra la integraron 40 pacientes, se dividió en 2 grupos Grupo 1 20 pacientes embarazadas con diagnóstico de circular de cordón o grupo problema; Grupo 2 20 pacientes con embarazo normal o grupo testigo. Se practicaron registros de frecuencia cardiaca fetal y contractilidad uterina durante 2 h. Para el análisis estadístico se utilizaron el programa SPSS® y las pruebas t de Student y Z. Resultados En el grupo problema la frecuencia cardiaca fetal (FCF) fue de 138 latidos por minuto (lat/min) y en el testigo de 135 lat/min. En el primer grupo, esta se incrementó 3 lat. Se calculó si la diferencia entre medias era o no significativa. Se utilizaron las pruebas de Z-score cuyo valor fue de 8,65 y p < 0,01 esta fue significativa. En los 2 grupos se calcularon los valores de la amplitud de las aceleraciones. Estas fueron semejantes 24 lat. La diferencia entre medias no fue significativa. El análisis comparativo entre el peso y la talla de los recién nacidos en el grupo problema fue de 3.100 g y la talla de 50,72 cm. En el testigo fue de 2.960 g y 49,77 cm respectivamente. La diferencia entre medias no fue significativa. A los recién nacidos se les valoró con la prueba de Apgar. En el grupo problema, durante el primer minuto la calificación tuvo un rango de 7-9 y en el quinto de 8-9. En el grupo testigo las calificaciones fueron semejantes. Se cuantificaron los dips tipos i y ii . De los primeros dips se registraron 3 y de los segundos 2, uno con gran amplitud y duración. No se registraron dips tipo iii . En ninguno de los partos hubo presencia de meconio. Conclusiones En la circular de cordón floja no hubo cambios significativos en la FCF. Circular de cordón apretada produjo dips tipo ii de gran amplitud (AU)
ABSTRACT

Objective:

To determine heart rate and the frequency of type i and ii dips in fetuses with coiling of funis. Study

design:

There were 40 patients in the sample, divided in two groups group 1 consisted of 20 pregnant women with a diagnosis of coiling of funis; group ii consisted of 20 patients with a normal pregnancy. Fetal heart rate (HR) and uterine contractility were recorded for 2 hours. For the statistical analysis, the SPSS® package, Z-score and Student’s t-test were used.

Results:

Fetal HR was 138 beats/min in group 1 and 135 beats/min in group ii. The difference between medians (Z-score) was 8.65, which was significant (P<.01).Amplitude and accelerations were calculated in both groups, with similar results (24 beats).The difference in means was not significant. The mean weight and height were compared in the two groups. Mean weight was 3,100 g in group 1 and 2,960 in group 1, while mean height was 50.72 cm in group i and 49.77 in group 2.The difference in means was not significant. Apgar tests were performed in both groups. In group 1, Apgar scores ranged from 7-9 at1 minute and from 8-9 at 5 minutes. Values were similar in group 2.Type i dips gave a reading of 3, and type ii dips a reading of 2 (one with marked height and duration). No type iii dips were observed. No meconium was found in any of the deliveries.

Conclusions:

In pregnancies with loosely coiled funises, there were no significant changes in fetal HR. In pregnancies with tightly coiled funises, type ii dips with wide amplitude and marked duration were found (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Contração Uterina / Frequência Cardíaca Fetal / Cordão Nucal / Hipóxia Fetal Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Feminino / Humanos / Gravidez Idioma: Espanhol Revista: Clín. investig. ginecol. obstet. (Ed. impr.) Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Politécnico Nacional/México / Secretaría de Salud del Dep del DF/México / Universidad Autónoma Metropolitana/México
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Contração Uterina / Frequência Cardíaca Fetal / Cordão Nucal / Hipóxia Fetal Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Feminino / Humanos / Gravidez Idioma: Espanhol Revista: Clín. investig. ginecol. obstet. (Ed. impr.) Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Politécnico Nacional/México / Secretaría de Salud del Dep del DF/México / Universidad Autónoma Metropolitana/México
...