Análisis causal e impacto de un error sistemático detectado en el consumo de trastuzumab / Causal analysis and impact of a systematic error detected about consumption associated with trastuzumab
Bujaldón Querejeta, Nuria; Camacho Romera, Dolores; Pomares Pastor, José Antonio; Sánchez Garnes, María; Martínez Ramírez, Mauricio; González Delgado, Mercedes.
Afiliação
  • Bujaldón Querejeta, Nuria; Hospital Universitario Sant Joan. Servicio de Farmacia. Alicante. España
  • Camacho Romera, Dolores; Hospital Universitario Sant Joan. Servicio de Farmacia. Alicante. España
  • Pomares Pastor, José Antonio; Hospital Universitario Sant Joan. Servicio de Farmacia. Alicante. España
  • Sánchez Garnes, María; Hospital Universitario Sant Joan. Servicio de Farmacia. Alicante. España
  • Martínez Ramírez, Mauricio; Hospital Universitario Sant Joan. Servicio de Farmacia. Alicante. España
  • González Delgado, Mercedes; Hospital Universitario Sant Joan. Servicio de Farmacia. Alicante. España
Farm. hosp ; 39(5): 309-313, sept.-oct. 2015. tab
Artigo em Espanhol | IBECS | ID: ibc-143215
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

determinar la causa de la diferencia constante entre las unidades teóricas de trastuzumab consumidas y las reales en una unidad de mezclas intravenosas.

Métodos:

se realizó un estudio del procedimiento completo manual y electrónico de la preparación de mezclas con trastuzumab mediante observación visual y revisión de los datos de control cuantitativo proporcionados por el sistema electrónico de preparación asistida y segura de la aplicación Farmis-Oncofarm.

Resultados:

se encontró diferencia entre el volumen óptimo del vial de trastuzumab que informa la ficha técnica del producto y el contenido en la ficha del medicamento de la aplicación. Además se encontró un defecto del volumen óptimo de las jeringas de 10 ml utilizadas en el proceso de reconstitución del vial.

Conclusiones:

el defecto de volumen óptimo de las jeringas de 10 ml utilizadas en el proceso de reconstitución es la causa del mayor número de viales reales consumidos en la preparación de mezclas con trastuzumab. Esto produce un impacto económico muy importante, estimando un sobrecoste anual de aproximadamente 46.508 Euros, sin provocar consecuencias negativas en el paciente (AU)
ABSTRACT

Objective:

determine the cause of the constant difference between the theoretical and real number of trastuzumab units consumed in an Intravenous Mixtures Unit.

Methods:

was studied the manual and electronic full procedure about preparing mixtures with trastuzumab. Was performed by visual observation and review of quantitative monitoring data from the electronic preparation support and safe system of the application Farmis-Oncofarm.

Results:

difference between the optimum volume of trastuzumab contained in the summary of product characteristics and the same included in Farmis_Oncofarm was found. Also found a defect of the optimum volume of 10ml syringes used in the reconstitution vials process.

Conclusions:

the default in the optimal volume of 10ml syringes used in the reconstitution process increases the real consumed units of trastuzumab. This produces a significant economic impact calculated in an annual additional cost in approximately 46.508 Euros without negative consequences for the patient (AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Erros de Medicação / Anticorpos Monoclonais Tipo de estudo: Guia de prática clínica / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Farm. hosp Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Sant Joan/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Erros de Medicação / Anticorpos Monoclonais Tipo de estudo: Guia de prática clínica / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Farm. hosp Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Sant Joan/España
...