Tres nuevas estrategias para mejorar la precisión de la estimulación vestibular calórica monotérmica / Three new strategies to improve the accuracy of monothermal caloric screening testing
Acta otorrinolaringol. esp
; 67(2): 75-82, mar.-abr. 2016. tab, graf
Artigo
em Espanhol
| IBECS
| ID: ibc-149408
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Objetivo:
Encontrar una forma de estimar el valor de paresia canalicular (PC) a través de la estimulación vestibular calórica monotérmica (EVCM) que pueda utilizarse en cualquier laboratorio, controlando el error que se produce al utilizarla.Método:
Se incluyó en este estudio a 2.304 pacientes de nuestro servicio a los cuales se les realizó una videonistagmografía con pruebas calóricas entre 2003 y 2011. El cálculo de la PC se realizó de 3 formas diferentes utilizando los valores de las 4 estimulaciones calóricas (forma bitérmica) o exclusivamente con los 2 valores de una misma temperatura (formas monotérmica caliente y fría respectivamente). Se estudiaron 3 estrategias para mejorar la precisión de la EVCM análisis de variables que empeoran la predicción, delimitación de un área gris de predicción deficiente y localización de un punto de separación entre sanos y enfermos de máxima utilidad.Resultados:
1) Corregir la fórmula de Jongkees con el valor del nistagmo espontáneo permite incluir como candidatos a la EVCM a sujetos con nistagmo espontáneo o inversión nistágmica. 2) Establecer una zona gris de predicción deficiente evita aproximadamente el 38% de las estimulaciones bitérmicas realizadas, con una sensibilidad y especificidad del 95%. 3) La máxima utilidad de la EVCM se obtiene al considerar como función vestibular normal la de sujetos con valores de EVCM caliente menores o iguales al 16%, suponiendo patológica una asimetría mayor del 20%.Conclusión:
Las nuevas herramientas estadísticas permiten a los clínicos tomar decisiones que afecten al manejo de sus pacientes basados en los resultados de la EVCM (AU)ABSTRACT
Objective:
The objective was to find a way to estimate the value of inter-ear difference (IED) through monothermal caloric screening testing (MCST) that can be used at any laboratory, controlling and minimising the resulting error.Methods:
We retrospectively included in this study 2304 patients from our department to whom a videonystagmography with caloric testing was performed between 2003 and 2011. The IED was calculated in 3 different ways Using the values of the 4 caloric stimulations (bithermal form) and using only the 2 same-temperature values (warm monothermal and cool monothermal forms). We studied 3 strategies to improve the accuracy of MCST Analysis of variables that could impair the prediction, delimitation of a grey area of insufficient prediction and location of a maximum utility cut-off point.Results:
Correcting Jongkees formula with the value for spontaneous nystagmus makes it possible to include subjects with spontaneous nystagmus or nystagmus inversion. Establishing 2 cut-off points to classify the subjects avoids approximately 38% of bithermal stimulations performed with a sensitivity and specificity of 95%. Maximum utility was obtained diagnosing as healthy those subjects with IED values lesser than or equal to 16% in warm MCST when the pathological IED was set as greater than 20%.Conclusion:
New statistical tools help clinicians to make decisions that affect their patients based on the results of MCST (AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Nistagmo Fisiológico
/
Testes Calóricos
/
Vertigem
Tipo de estudo:
Estudo diagnóstico
/
Estudo prognóstico
/
Estudo de rastreamento
Limite:
Adulto
/
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Acta otorrinolaringol. esp
Ano de publicação:
2016
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital Universitario Virgen del Rocío/España
/
Universidad de Sevilla/España