Clínica, diagnóstico, tratamiento y evolución de la infección de las endoprótesis aórticas del sector torácico y abdominal / Clinical features, diagnosis, treatment, and outcomes of thoracic and abdominal aortic endograft infections
Castejón, B; Reyes Valdivia, A; Garnica Ureña, M; Romero Lozano, MA; Ocaña Guaita, J; Gandarias Zuñiga, C.
Afiliação
  • Castejón, B; Hospital Ramón y Cajal. Servicio de Angiología y Cirugía Vascular. Madrid. España
  • Reyes Valdivia, A; Hospital Ramón y Cajal. Servicio de Angiología y Cirugía Vascular. Madrid. España
  • Garnica Ureña, M; Hospital Ramón y Cajal. Servicio de Angiología y Cirugía Vascular. Madrid. España
  • Romero Lozano, MA; Hospital Ramón y Cajal. Servicio de Angiología y Cirugía Vascular. Madrid. España
  • Ocaña Guaita, J; Hospital Ramón y Cajal. Servicio de Angiología y Cirugía Vascular. Madrid. España
  • Gandarias Zuñiga, C; Hospital Ramón y Cajal. Servicio de Angiología y Cirugía Vascular. Madrid. España
Angiología ; 68(5): 379-387, sept.-oct. 2016. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-155984
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

INTRODUCCIÓN:

Las infecciones de endoprótesis aórticas son infrecuentes pero devastadoras. El tratamiento no está estandarizado, resultando una decisión compleja y en muchos casos urgente.

OBJETIVOS:

Describir el diagnóstico, el tratamiento y la evolución de los casos de infección de endoprótesis aórtica abdominal (EVAR) y torácica (TEVAR) tratados en un único centro.

MÉTODOS:

Estudio observacional, retrospectivo, descriptivo que incluyó pacientes con infección endoprotésica tratados entre 1998 y 2015. Se recogió la indicación del implante inicial, intervenciones posteriores, tiempo hasta la infección, clínica, pruebas complementarias, tratamiento y evolución.

RESULTADOS:

Registramos 9 infecciones 5 EVAR (1,2%) y 4 TEVAR (4,2%). La mediana de edad fue de 77 años (rango, 62-85). Detectamos 5 infecciones tras implantes urgentes (5 de 9) y 3 tras intervenciones secundarias (3 de 9). La mediana de tiempo hasta la infección fue de 3,5 meses (rango, 0-109,5). Realizamos 7 explantes de endoprótesis (5 EVAR y 2 TEVAR), con reparación in situ con prótesis de dacrón-plata (n=5) o bypass axilobifemoral (n=2). En 2 TEVAR el tratamiento fue conservador por elevado riesgo quirúrgico dadas sus comorbilidades. La mortalidad a 30 días fue del 44,4% (4 de 9 pacientes), todos tras tratamiento quirúrgico. La mortalidad global fue del 66,6% (6 de 9 pacientes). Solo falleció un paciente con tratamiento conservador tras 2 años de seguimiento debido a una fístula aortoesofágica. Tres pacientes están en seguimiento (2 explantes y uno conservador) tras 121, 74 y 51 meses, respectivamente.

CONCLUSIONES:

La mortalidad de los pacientes con infección endoprotésica es elevada, independientemente del tratamiento. El tratamiento conservador es una buena opción en nuestra experiencia, y la cirugía, una alternativa que debería emplearse en función de las características del paciente
ABSTRACT

INTRODUCTION:

Aortic endograft infections are uncommon. However, they are usually life-threatening. Treatment is not standardised, making this disease complex, and in most cases, an urgent situation.

OBJECTIVES:

To describe the diagnosis, treatment, and follow-up of all cases diagnosed with infected aortic endograft (abdominal-EVAR, and thoracic-TEVAR) in our Hospital.

METHODS:

An observational and retrospective study was conducted using data collected between 1998 and 2015. A descriptive analysis is presented on the primary indication for treatment, secondary procedures, the time-lapse between the diagnosis and primary treatment, type of repair, follow-up, and mortality.

RESULTS:

Of the 9 patients with infected aortic endografts, 5 were with EVAR (1.2%) and 4 with TEVAR (4.2%). The median age was 77 years (range, 62-85). Five patients received a primary urgent endograft (5 of 9). Three patients had secondary procedures before the infection diagnosis (3 of 9). The median time between primary repair and diagnosis was 3.5 months (range, 0-109.5). Explantation was performed on 7 patients. Two patients received medical treatment due to their increased surgical risk. The 30 day mortality was 44.4% (4 of 9 patients), and the overall mortality was 66.6% (6 of 9 patients). One patient with medical treatment died due to an aortic-oesophageal fistula after 2 years of follow-up. Three patients are still alive (2 explantations, and 1 with medical treatment) after 121, 74, and 51 months, respectively.

CONCLUSIONS:

Endograft infections mortality is high, despite the treatment used. Medical treatment is a good choice in our experience. Surgical treatment is an alternative depending on the fitness and comorbidities of the patient
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: Agenda de Saúde Sustentável para as Américas Problema de saúde: Objetivo 10: Doenças transmissíveis Base de dados: IBECS Assunto principal: Prótese Vascular / Stents / Infecções Relacionadas à Prótese Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Angiología Ano de publicação: 2016 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Ramón y Cajal/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: Agenda de Saúde Sustentável para as Américas Problema de saúde: Objetivo 10: Doenças transmissíveis Base de dados: IBECS Assunto principal: Prótese Vascular / Stents / Infecções Relacionadas à Prótese Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Angiología Ano de publicação: 2016 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Ramón y Cajal/España
...