Pseudoaneurisma de arteria segmentaria lumbar tras introducción de tornillo transpedicular L5. Una rara complicación vascular / Lumbar segmental artery pseudoaneurysm after L5 pedicle screw placement. A rare vascular complication
Álvarez Postigo, M; Pizones Arce, J; Izquierdo Núñez, E.
Afiliação
  • Álvarez Postigo, M; Hospital Universitario de Getafe. Getafe. España
  • Pizones Arce, J; Hospital Universitario La Paz. Madrid. España
  • Izquierdo Núñez, E; Hospital Universitario de Getafe. Getafe. España
Rev. Esp. Cir. Ortop. Traumatol. (Ed. Impr.) ; 61(6): 436-440, nov.-dic. 2017. ilus
Artigo em Espanhol | IBECS | ID: ibc-168640
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
La fusión instrumentada lumbar por vía posterior se realiza de manera habitual hoy en día, aunque en algunas ocasiones puede inducir complicaciones que pueden llegar a ser devastadoras. Una de las causas, aunque poco frecuentes, de complicación mayor es la malposición de los tornillos pediculares, de ahí la importancia de ser metódicos a la hora de su colocación, comprobando el correcto labrado del trayecto y su introducción. Presentamos un caso de sangrado masivo tras la introducción de un tornillo pedicular lumbar durante una cirugía por estenosis de canal. La malposición del tornillo conllevó la inestabilidad hemodinámica intraoperatoria de la paciente tras el fracaso de los métodos habituales de control de sangrado en el campo quirúrgico. La realización de una TAC con contraste evidenció lesión de la arteria intersegmentaria lumbar que fue finalmente controlada mediante embolización e implantación de coil vascular (AU)
ABSTRACT
Posterior lumbar screw fixation is a common surgical procedure nowadays. However, it can sometimes produce complications that can be devastating. One of the less common causes of major complication is the misplacement of a pedicle screw. This highlights the importance of being methodical when placing pedicle screws, and checking that the pathway has been created correctly and their placement. We present a case of a massive bleed after a pedicular screw placement during lumbar canal stenosis surgery. Screw malposition led to intraoperative haemodynamic instability after failed attempts to control bleeding in the surgical site. Contrast enhanced CT imaging revealed a lumbar intersegmentary artery injury that was eventually controlled by means of a coil embolisation (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Parafusos Ósseos / Falso Aneurisma / Embolização Terapêutica Limite: Idoso / Feminino / Humanos Idioma: Espanhol Revista: Rev. Esp. Cir. Ortop. Traumatol. (Ed. Impr.) Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario La Paz/España / Hospital Universitario de Getafe/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Parafusos Ósseos / Falso Aneurisma / Embolização Terapêutica Limite: Idoso / Feminino / Humanos Idioma: Espanhol Revista: Rev. Esp. Cir. Ortop. Traumatol. (Ed. Impr.) Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario La Paz/España / Hospital Universitario de Getafe/España
...