Correlación entre la saturación de oxihemoglobina por pulsioximetría y la presión arterial de oxígeno en pacientes con insuficiencia respiratoria aguda / Correlation between oxyhaemoglobin saturation by pulse oximetry and partial pressure of oxygen in patients with acute respiratory failure
Rev. clín. esp. (Ed. impr.)
; 217(9): 522-525, dic. 2017. tab, graf
Artigo
em Espanhol
| IBECS
| ID: ibc-169078
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Objetivos. Averiguar la correlación entre la presión arterial de oxígeno (PaO2) y la saturación de la oxihemoglobina por pulsioximetría (SpO2) en pacientes que acuden a Urgencias con sospecha de insuficiencia respiratoria aguda. Material y métodos. Estudio prospectivo, observacional y multicéntrico realizado en los servicios de Urgencias de 3 hospitales españoles. Resultados. Se incluyeron 166 pacientes, que presentaron unos valores medios±desviación estándar de PaO2, SpO2 y fracción inspiratoria de O2 (FiO2) de 61,64±17,3mmHg, 87,61±8,8% y 0,28±0,15%, respectivamente. La mediana de los cocientes PaO2/FiO2 y SpO2/FiO2 fue de 256,6 y 359,2, respectivamente. La correlación entre la PaO2/FiO2 y la SpO2/FiO2 fue de 0,745 (p<0,001). Conclusiones. La SpO2/FiO2 se puede utilizar como estimación de la PaO2/FiO2 y conocer el estado de oxigenación del paciente con insuficiencia respiratoria aguda (AU)
ABSTRACT
Objectives. To ascertain the correlation between the partial pressure of oxygen (PaO2) and oxyhaemoglobin saturation by pulse oximetry (SpO2) in patients who were admitted to the emergency department with suspected acute respiratory failure. Material and methods. A prospective, observational multicentre study was conducted in the emergency departments of 3 Spanish hospitals. Results. The study included 166 patients who presented mean±standard deviation PaO2, SpO2 and fraction of inspired oxygen (FiO2) values of 61.64±17.3mmHg, 87.61±8.8% and 0.28±0.15%, respectively. The median PaO2/FiO2 and SpO2/FiO2 ratios were 256.6 and 359.2, respectively. The correlation between PaO2/FiO2 and the SpO2/FiO2 was 0.745 (P<.001). Conclusions. The SpO2/FiO2 ratio can be used to calculate PaO2/FiO2 and determine the oxygenation state of patients with acute respiratory failure (AU)
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Insuficiência Respiratória
/
Gasometria
/
Oxiemoglobinas
/
Oximetria
Tipo de estudo:
Ensaio clínico controlado
/
Estudo observacional
Limite:
Humanos
Idioma:
Espanhol
Revista:
Rev. clín. esp. (Ed. impr.)
Ano de publicação:
2017
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital General Universitario Los Arcos del Mar Menor/España
/
Hospital General Universitario Reina Sofía/España
/
Hospital de la Vega Lorenzo Guirao/España