Your browser doesn't support javascript.
loading
Serum periostin is not related to asthma predictive index
Castro-Rodriguez, JA; Atton, I; Villarroel, G; Serrano, CA.
Afiliação
  • Castro-Rodriguez, JA; Pontificia Universidad Católica de Chile. School of Medicine. Division of Pediatrics. Santiago. Chile
  • Atton, I; Pontificia Universidad Católica de Chile. School of Medicine. Division of Pediatrics. Santiago. Chile
  • Villarroel, G; Pontificia Universidad Católica de Chile. School of Medicine. Division of Pediatrics. Santiago. Chile
  • Serrano, CA; Pontificia Universidad Católica de Chile. School of Medicine. Division of Pediatrics. Santiago. Chile
Allergol. immunopatol ; 46(3): 235-240, mayo-jun. 2018. tab, graf
Artigo em Inglês | IBECS | ID: ibc-172942
Biblioteca responsável: ES1.1
Localização: BNCS
ABSTRACT

BACKGROUND:

In contrast to adult asthmatic patients, studies on the role of serum periostin levels in schoolchildren with asthma are still conflictive, and very few studies have been performed in pre-schoolers. The aim of this study was to compare serum periostin levels in recurrent wheezer pre-schoolers according to their asthma predictive index (API) condition.

METHODS:

We performed a case-control study enrolling pre-schoolers with recurrent wheezing episodes (>3 episodes confirmed by physician) presented at one paediatric clinic in Santiago, Chile. The population was divided according to stringent API criteria into positive or negative.

RESULTS:

In a one-year period, 60 pre-schoolers were enrolled. After excluding 12 (due to not fulfilment of inclusion criteria or refusal of blood sample extraction), 48 remaining pre-schoolers (27 males, age range from 24 to 71 months) completed the study; 34 were API positive and 14 were API negative. There were no significant differences in demographics between groups. The level of serum periostin levels for pre-schoolers with positive API and negative API were (median 46.7 [25.5-83.1] and 67.5 [20.5-131.8], p = 0.9, respectively). The area under the curve for the serum periostin levels for predict positive API was 0.5, 95% CI [0.29-0.70], p = 0.9. No significant correlation between serum periostin levels and peripheral blood eosinophils was found.

CONCLUSION:

Serum periostin levels were no significantly different between wheezer pre-schoolers with positive and negative API. More studies are needed to confirm this

finding:

RESUMEN
No disponible
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Asma / Biomarcadores / Moléculas de Adesão Celular Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Criança, pré-escolar / Feminino / Humanos / Masculino Idioma: Inglês Revista: Allergol. immunopatol Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Pontificia Universidad Católica de Chile/Chile
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Asma / Biomarcadores / Moléculas de Adesão Celular Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Criança, pré-escolar / Feminino / Humanos / Masculino Idioma: Inglês Revista: Allergol. immunopatol Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Pontificia Universidad Católica de Chile/Chile
...