Your browser doesn't support javascript.
loading
Control del formaldehído, xileno y compuestos orgánicos volátiles mediante el sistema integral de friocongelación y fotocatalización / Prevention and control of formaldehyde, xylene and volatile organic compounds by photocatalysis and freezing integral system mileida
Peñalver Paolini, Andreina; Mazón Cuadrado, Luis Carlos; Berrocal Fernández, Pilar.
Afiliação
  • Peñalver Paolini, Andreina; Hospital Universitario de Fuenlabrada. Madrid. España
  • Mazón Cuadrado, Luis Carlos; Hospital Universitario de Fuenlabrada. Madrid. España
  • Berrocal Fernández, Pilar; ValoraPrevención. Madrid. España
Med. segur. trab ; 63(249): 319-330, oct.-dic. 2017. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-173303
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Antecedentes En anatomía patológica, existen variedad de agentes químicos que deben ser controlados. Por su potencial cancerígeno destacan el Formaldehído (CH2 O), Xileno y los Compuestos Orgánicos Volátiles (COVs).

Objetivo:

Valorar la eficacia del uso de purificadores mediante la fotocatalización y los sistemas de friocongelación, para el control de los niveles de exposición a CH2 O, Xileno y COVs. Objetivo Secundario Comparar mediciones de Formaldehído con otros 3 hospitales de la Comunidad de Madrid.

Metodología:

Se realizaron 26 mediciones ambientales en Anatomía Patológica del Hospital Universitario de Fuenlabrada (HUF), en febrero del año 2017 y en marzo del mismo año, posterior a la instalación de los purificadores y sistemas de friocongelación, en las áreas de laboratorio y sala de tallado. Se valora Xileno y COVs con el método PID (detector de fotoionización, PID por sus siglas en inglés, PhotoIonization Detector) y de CH2 O a través de un Sistema de Detección de Gas. Como criterio para valorar la exposición a COVs se tomó como gas de referencia el isobutileno con un VLA-EC de 100 ppm. Para el Xileno se compararon los resultados con el VLA-EC 100 ppm y para el CH2 O con el VLA-EC de 0,3 ppm, establecidos en la guía de «Límites de Exposición Profesional para Agentes Químicos» del Instituto Nacional de Seguridad e Higiene en el Trabajo.

Resultados:

Los niveles de exposición previos no superaban los valores límites. Se observó que tras la implantación de las medidas preventivas colectivas estos valores disminuyeron, obteniéndose resultados estadísticamente significativos COVs (p= 0.0002; IC 95% 2.393- 5.506), Xileno (p= 0.0002; IC 95% 1.021- 2.359) y CH2 O (p= 0.0004; IC 95% 0.210-0.350).

Conclusiones:

El sistema integral de friocongelación y purificación mediante fotocatalización optimizan el control de la exposición a dichos agentes químicos, anulando las fuentes de emisión
ABSTRACT

Background:

In anatomical pathology, there are a variety of chemical agents that must be controlled due to their carcinogenic potential, such as formaldehyde (CH2 O), Xylene and Volatile Organic Compounds (VOCs).

Objective:

To evaluate the effectiveness use of purifiers by photocatalysis and freezing systems for the control of exposure levels to CH2 O, Xylene and VOCs. Secondary

Objective:

To compare the Formaldehyde measurements among other 3 hospitals in the Community of Madrid.

Methodology:

26 environmental assessments were performed in the Anatomical Pathology Department at the Hospital Universitario de Fuenlabrada (HUF, Madrid), in February 2017 and in March of the same year, after installing the purifiers and the freezing systems in the laboratory and room carved areas. Xylene and VOCs are evaluated using the PID method (Photo-Ionization Detector) and CH2 O through a Gas Detection System. As a criterion for assessing exposure to VOCs, isobutylene was used as a reference gas with a VLA-EC of 100 ppm. For Xylene the results were compared with the VLA-EC 100 ppm and for the CH2 O with the VLA-EC of 0.3 ppm, established in the guide of "Occupational Exposure Limits for Chemical Agents" from the National Institute of Occupational Safety and Health.

Results:

Previous exposure levels did not exceed the limit values. It was observed that these values decreased after the implementation of collective preventive measures, obtaining statistically significant

results:

VOCs (p = 0,0002, 95% CI 2,393-5,506), Xylene (P = 0,0002, 95% CI 1,021-2,359) and CH2 O (p = 0,0004, 95% CI 0,210-0,350).

Conclusions:

The integrated system of freeze-thawing and photocatalytic purification optimize the exposure control to these chemical agents, canceling emission sources
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: ODS3 - Meta 3.9 Reduzir as mortes por produtos químicos y contaminação do ar, água e solo / ODS3- Meta 3D Reforçar a capacidade de alerta precoce, redução e gestão de riscos de saúde nacionais e globais Problema de saúde: Exposições Ocupacionais / Riscos Biológicos Base de dados: IBECS Assunto principal: Dispositivos de Proteção Respiratória / Xilenos / Contenção de Riscos Biológicos / Compostos Orgânicos Voláteis / Formaldeído Limite: Humanos Idioma: Espanhol Revista: Med. segur. trab Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario de Fuenlabrada/España / ValoraPrevención/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: ODS3 - Meta 3.9 Reduzir as mortes por produtos químicos y contaminação do ar, água e solo / ODS3- Meta 3D Reforçar a capacidade de alerta precoce, redução e gestão de riscos de saúde nacionais e globais Problema de saúde: Exposições Ocupacionais / Riscos Biológicos Base de dados: IBECS Assunto principal: Dispositivos de Proteção Respiratória / Xilenos / Contenção de Riscos Biológicos / Compostos Orgânicos Voláteis / Formaldeído Limite: Humanos Idioma: Espanhol Revista: Med. segur. trab Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario de Fuenlabrada/España / ValoraPrevención/España
...