Your browser doesn't support javascript.
loading
Valor pronóstico de la pulsioximetría nocturna en pacientes con insuficiencia cardiaca / Prognostic value of nocturnal pulse oximetry in patients with heart failure
Rivera-López, Ricardo; Jordán-Martínez, Laura; López-Fernández, Silvia; Rivera-Fernandez, Ricardo; Tercedor, Luis; Sáez-Roca, Germán.
Afiliação
  • Rivera-López, Ricardo; Hospital Universitario Virgen de las Nieves. Servicio de Cardiología. Granada. España
  • Jordán-Martínez, Laura; Hospital Universitario Virgen de las Nieves. Servicio de Cardiología. Granada. España
  • López-Fernández, Silvia; Hospital Universitario Virgen de las Nieves. Servicio de Cardiología. Granada. España
  • Rivera-Fernandez, Ricardo; Complejo Hospitalario de Jaén. Unidad de Cuidados Intensivos. Jaén. España
  • Tercedor, Luis; Hospital Universitario Virgen de las Nieves. Servicio de Cardiología. Granada. España
  • Sáez-Roca, Germán; Hospital Universitario Virgen de las Nieves. Servicio de Neumología. Granada. España
Med. clín (Ed. impr.) ; 150(10): 383-386, mayo 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-173440
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Introducción y

objetivos:

Analizar el valor pronóstico de la hipoxemia nocturna, evaluada mediante pulsioximetría nocturna portátil, en pacientes ingresados por insuficiencia cardiaca y su relación con la mortalidad y el reingreso hospitalario.

Métodos:

Incluimos a 38 pacientes ingresados de manera consecutiva en nuestra unidad con el diagnóstico de insuficiencia cardiaca descompensada. La pulsioximetría se consideró positiva para hipoxemia cuando se registraron más de 10 desaturaciones a la hora durante el sueño. Se realizó seguimiento durante 30,3 (desviación estándar [DE] 14,2) meses, el objetivo principal fue un endpoint combinado de mortalidad por cualquier causa y reingreso por insuficiencia cardiaca.

Resultados:

La edad media fue de 70,7 (DE 10,7) años; el 63,3% eran varones. La pulsioximetría fue considerada positiva para hipoxemia en 27 (71%) pacientes. Los pacientes con una pulsioximetría positiva presentaron con mayor frecuencia el endpoint combinado (9.1% [1] vs. 61,5% [16]; p = 0,003). Tras el análisis multivariable, la hipoxemia nocturna continuó estando relacionada con el endpoint combinado (HR = 8,37; 1,19-68,4; p = 0,03).

Discusión:

Los pacientes ingresados por insuficiencia cardiaca e hipoxemia nocturna medida con pulsioxímetro portátil presentan un riesgo aumentado de reingreso y muerte
ABSTRACT
Introduction and

objectives:

To analyze the prognostic value of nocturnal hypoxemia measured with portable nocturnal pulse-oximetry in patients hospitalized due to heart failure and its relation to mortality and hospital readmission.

Methods:

We included 38 patients who were admitted consecutively to our unit with the diagnosis of decompensated heart failure. Pulse-oximetry was considered positive for hypoxemia when more than 10 desaturations per hour were recorded during sleep. Follow-up was performed for 30.3 (standard deviation [SD] 14.2) months, the main objective being a combined endpoint of all-cause mortality and hospital readmission due to heart failure.

Results:

The average age was 70.7 (SD 10.7) years, 63.3% were males. Pulse-oximetry was considered positive for hypoxemia in 27 (71%) patients. Patients with positive pulse-oximetry had the most frequent endpoint (9.1% [1] vs. 61.5% [16], P = 0.003). After multivariate analysis, continuous nocturnal hypoxemia was related to the combined endpoint (HR = 8.37, 1.19-68.4, P = 0.03).

Discussion:

Patients hospitalized for heart failure and nocturnal hypoxemia measured with portable pulse-oximeter have an increased risk of hospital readmission and death
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Pulso Arterial / Monitorização Transcutânea dos Gases Sanguíneos / Insuficiência Cardíaca Tipo de estudo: Estudo prognóstico Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Med. clín (Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario de Jaén/España / Hospital Universitario Virgen de las Nieves/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Pulso Arterial / Monitorização Transcutânea dos Gases Sanguíneos / Insuficiência Cardíaca Tipo de estudo: Estudo prognóstico Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Med. clín (Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario de Jaén/España / Hospital Universitario Virgen de las Nieves/España
...