Valor pronóstico de la pulsioximetría nocturna en pacientes con insuficiencia cardiaca / Prognostic value of nocturnal pulse oximetry in patients with heart failure
Med. clín (Ed. impr.)
; 150(10): 383-386, mayo 2018. tab, graf
Artigo
em Espanhol
| IBECS
| ID: ibc-173440
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción y objetivos:
Analizar el valor pronóstico de la hipoxemia nocturna, evaluada mediante pulsioximetría nocturna portátil, en pacientes ingresados por insuficiencia cardiaca y su relación con la mortalidad y el reingreso hospitalario.Métodos:
Incluimos a 38 pacientes ingresados de manera consecutiva en nuestra unidad con el diagnóstico de insuficiencia cardiaca descompensada. La pulsioximetría se consideró positiva para hipoxemia cuando se registraron más de 10 desaturaciones a la hora durante el sueño. Se realizó seguimiento durante 30,3 (desviación estándar [DE] 14,2) meses, el objetivo principal fue un endpoint combinado de mortalidad por cualquier causa y reingreso por insuficiencia cardiaca.Resultados:
La edad media fue de 70,7 (DE 10,7) años; el 63,3% eran varones. La pulsioximetría fue considerada positiva para hipoxemia en 27 (71%) pacientes. Los pacientes con una pulsioximetría positiva presentaron con mayor frecuencia el endpoint combinado (9.1% [1] vs. 61,5% [16]; p = 0,003). Tras el análisis multivariable, la hipoxemia nocturna continuó estando relacionada con el endpoint combinado (HR = 8,37; 1,19-68,4; p = 0,03).Discusión:
Los pacientes ingresados por insuficiencia cardiaca e hipoxemia nocturna medida con pulsioxímetro portátil presentan un riesgo aumentado de reingreso y muerteABSTRACT
Introduction and objectives:
To analyze the prognostic value of nocturnal hypoxemia measured with portable nocturnal pulse-oximetry in patients hospitalized due to heart failure and its relation to mortality and hospital readmission.Methods:
We included 38 patients who were admitted consecutively to our unit with the diagnosis of decompensated heart failure. Pulse-oximetry was considered positive for hypoxemia when more than 10 desaturations per hour were recorded during sleep. Follow-up was performed for 30.3 (standard deviation [SD] 14.2) months, the main objective being a combined endpoint of all-cause mortality and hospital readmission due to heart failure.Results:
The average age was 70.7 (SD 10.7) years, 63.3% were males. Pulse-oximetry was considered positive for hypoxemia in 27 (71%) patients. Patients with positive pulse-oximetry had the most frequent endpoint (9.1% [1] vs. 61.5% [16], P = 0.003). After multivariate analysis, continuous nocturnal hypoxemia was related to the combined endpoint (HR = 8.37, 1.19-68.4, P = 0.03).Discussion:
Patients hospitalized for heart failure and nocturnal hypoxemia measured with portable pulse-oximeter have an increased risk of hospital readmission and death
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Pulso Arterial
/
Monitorização Transcutânea dos Gases Sanguíneos
/
Insuficiência Cardíaca
Tipo de estudo:
Estudo prognóstico
Limite:
Idoso
/
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Med. clín (Ed. impr.)
Ano de publicação:
2018
Tipo de documento:
Artigo
Instituição/País de afiliação:
Complejo Hospitalario de Jaén/España
/
Hospital Universitario Virgen de las Nieves/España