Your browser doesn't support javascript.
loading
Nueva técnica de masaje cardíaco en lactantes / A new chest compression technique in infants
Rodriguez-Ruiz, E; Guerra Martín, V; Abelairas-Gómez, C; Sampedro Vidal, F; Gómez González, C; Barcala-Furelos, R; Rodríguez-Nuñez, A.
Afiliação
  • Rodriguez-Ruiz, E; Universidad de Santiago de Compostela. Servicio Gallego de Salud (SERGAS). Hospital Clínico Universitario de Santiago de Compostela. Servicio de Medicina Intensiva. Santiago de Compostela. España
  • Guerra Martín, V; Hospital Universitario de Canarias. Servicio de Pediatría. Santa Cruz de Tenerife. España
  • Abelairas-Gómez, C; Universidad de Santiago de Compostela. Instituto de Investigación de Santiago (IDIS). Soporte Vital y Simulación. Grupos de investigación CLINURSID. Santiago de Compostela. España
  • Sampedro Vidal, F; Universidad de Santiago de Compostela. Facultad de Enfermería. Santiago de Compostela. España
  • Gómez González, C; Complejo Hospitalario Universitario de Coruña. Servicio de Pediatría. La Coruña. España
  • Barcala-Furelos, R; Universidad de Vigo. Facultad de Ciencias de la Educación Física y el Deporte. Grupo de Investigación REMOSS. Vigo. España
  • Rodríguez-Nuñez, A; Universidad de Santiago de Compostela. Instituto de Investigación de Santiago (IDIS). Soporte Vital y Simulación. Grupos de investigación CLINURSID. Santiago de Compostela. España
Med. intensiva (Madr., Ed. impr.) ; 43(6): 346-351, ago.-sept. 2019. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-183253
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Comparar en un maniquí de lactante la calidad de las compresiones torácicas según el método tradicional (MT) o según la nueva técnica de 2pulgares con puños cerrados (NM).

Diseño:

Estudio controlado, aleatorizado y cruzado en profesionales. Ámbito Hospital Universitario con UCI Pediátrica del norte de España. Participantes Residentes y enfermeros de Pediatría, habiendo superado un curso de RCP básica y avanzada pediátrica. Intervenciones Análisis cuantitativo de calidad de compresiones torácicas en escenario de RCP en lactante durante 2 min, mediante el sistema SimPad(R) con SkillReporter(TM) de Laerdal. Variables de interés principales Frecuencia media y porcentaje de compresiones en rango recomendada, profundidad media y porcentaje de compresiones en rango recomendado, porcentaje de compresiones con descompresión adecuada y porcentaje de compresiones realizadas con los dedos en el centro del tórax.

Resultados:

La calidad global de las compresiones (NM 84,2±23,7% vs. MT 80,1±25,4% [p=0,25; no sig.]), el porcentaje de compresiones con profundidad correcta (NM 59,9±35,8% vs. MT 59,5±35,7% [p=0,76; no sig.]), la profundidad media alcanzada (NM 37,3±3,8mm vs. MT 36±5,3mm [p=0,06; no sig.]), el porcentaje de reexpansión completa de la caja torácica (NM 94,4±9,3% vs. MT 92,4±18,3% [p=0,58; no sig.]) y el porcentaje de compresiones con la frecuencia recomendada (NM 62,2±34,6% vs. MT 51±37,2% [p=0,13; no sig.]) fueron similares con los 2métodos.

Conclusiones:

La calidad de compresiones torácicas con el nuevo método (pulgares con los puños cerrados) es similar a la obtenida con el método tradicional
ABSTRACT

Objective:

To compare the quality of chest compressions performed according to the classical technique (MT) versus a new technique (NM) (compression with 2thumbs with closed fists) in an infant manikin.

Design:

A controlled, randomized cross-over study was carried out in professionals assisting pediatric patients.

Setting:

A University Hospital with a Pediatric ICU in the north of Spain.

Participants:

Residents and nurses in Pediatrics who had completed a basic and an advanced pediatric cardiopulmonary resuscitation course.

Interventions:

Quantitative analysis of the variables referred to chest compression quality in a 2-minute cardiopulmonary resuscitation scenario in infants. Laerdal's SimPad(R) with SkillReporter(TM) system was used. Main variables of interest Mean rate and percentage of compressions in the recommended rate range, mean depth and percentage of compressions within the depth range of recommendations, percentage of compressions with adequate decompression, and percentage of compressions performed with the fingers in the center of the chest.

Results:

Global quality of the compressions (NM 84.2±23.7% vs. MT 80.1±25.4% [p=0.25; p=ns]), percentage of compressions with correct depth (NM 59.9±35.8% vs. MT 59.5±35.7% [p=0.76; p=ns]), mean depth reached (NM 37.3±3.8mm vs. MT 36±5.3mm [p=0.06; p=ns]), percentage of complete re-expansion of the chest (NM 94.4±9.3% vs. MT 92.4±18.3% [p=0.58; p=ns]), and percentage of compressions with the recommended rate (NM 62.2±34.6% vs. MT 51±37.2% [p=0.13; p=ns]) proved similar with both methods.

Conclusions:

The quality of chest compressions with the new method (thumbs with closed fists) is similar to that afforded by the traditional

method:

Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Simulação de Paciente / Reanimação Cardiopulmonar / Massagem Cardíaca / Manequins Limite: Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Med. intensiva (Madr., Ed. impr.) Ano de publicação: 2019 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario de Coruña/España / Hospital Universitario de Canarias/España / Universidad de Santiago de Compostela/España / Universidad de Vigo/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Simulação de Paciente / Reanimação Cardiopulmonar / Massagem Cardíaca / Manequins Limite: Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Med. intensiva (Madr., Ed. impr.) Ano de publicação: 2019 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario de Coruña/España / Hospital Universitario de Canarias/España / Universidad de Santiago de Compostela/España / Universidad de Vigo/España
...