Your browser doesn't support javascript.
loading
Parámetros basales de la espirometría que pueden influir en la prueba de broncodilatación / Baseline spirometry parameters that can influence the bronchodilation test
Rodríguez Clérigo, I; Nieto Rojas, I; Mota Santana, R; Abarca López, MJ; Orueta Sánchez, R; Alonso Moreno, FJ; Segura Fragoso, A.
Afiliação
  • Rodríguez Clérigo, I; Centro de Salud Sillería. Medicina de Familia. Toledo. España
  • Nieto Rojas, I; Centro de Salud Sillería. Medicina de Familia. Toledo. España
  • Mota Santana, R; Centro de Salud Sillería. Medicina de Familia. Toledo. España
  • Abarca López, MJ; Centro de Salud Sillería. Toledo. España
  • Orueta Sánchez, R; Centro de Salud Sillería. Medicina de Familia. Toledo. España
  • Alonso Moreno, FJ; Centro de Salud Sillería. Medicina de Familia. Toledo. España
  • Segura Fragoso, A; Instituto de Ciencias de la Salud. Servicio de Investigación. Talavera de la Reina. España
SEMERGEN, Soc. Esp. Med. Rural Gen. (Ed. Impr.) ; 45(6): 375-381, sept. 2019. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-188531
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

OBJETIVO:

Estudiar si los parámetros basales de la espirometría forzada pueden influir en la positividad de la prueba de broncodilatación (PBD) y si esto pudiera influir en futuros criterios de positividad. MATERIAL Y

MÉTODOS:

Estudio descriptivo transversal multicéntrico con emplazamiento en Atención Primaria. Fueron incluidos todos los pacientes derivados por su médico de familia, para la realización de espirometría forzada por tabaquismo, síntomas respiratorios o seguimiento de enfermedades respiratorias, entre los meses de junio de 2015 y febrero de 2017. A todos ellos se les realizó una espirometría forzada con PBD.

RESULTADOS:

Se incluyeron 295 pacientes, con una edad media de 53,4+/-15,5 años, el 62% fueron hombres. En el 20% de las espirometrías se obtuvo un patrón obstructivo; presentando el 67,5% una obstrucción leve, 18% moderada, 9,6% moderada-grave y un 4,8% muy grave. El 8,8% de las espirometrías obtuvieron PBD positiva; 11,2% fueron positivas únicamente en volumen y el 17,6% fueron positivas únicamente en porcentaje. Se observó que los pacientes con una PBD positiva en porcentaje presentaban de forma basal menor volumen espiratorio forzado en el primer segundo (1,66 l/sg vs.2,74 l/sg; p <0,001), y menor capacidad vital forzada (2,85 l vs.3,73 l; p < 0,001). Los pacientes con PBD positiva en volumen presentaban menor volumen espiratorio forzado en el primer segundo (2,59 l/sg vs.2,62 l/sg; p <0,001), y mayor capacidad vital forzada (3,89 l vs.3,58 l; p < 0,001).

CONCLUSIONES:

El volumen espiratorio forzado en el primer segundo y la capacidad vital forzada basales influyen en la positividad de la PBD. Debería valorarse esta circunstancia a la hora de establecer los criterios de positividad de la PBD
ABSTRACT

OBJECTIVE:

To determine whether the baseline parameters of forced spirometry can influence the positivity of the bronchodilation test (BDT), and whether this could have an influence in future positivity criteria. MATERIAL AND

METHODS:

A descriptive, cross-sectional study was conducted in a Primary Care setting. It included all patients referred by their family doctor to perform a forced spirometry test due to smoking, respiratory symptoms, or follow-up of respiratory diseases, between the months of June 2015 and February 2017. All of them were subjected to a forced spirometry with a BDT.

RESULTS:

A total of 295 patients were included, with a mean age 53.4+/-15.5 years, and 62% were male. An obstructive pattern was obtained in 20% of the spirometries, with 67.5% presenting with a mild obstruction, 18% a moderate, 9.6% moderate to severe, and 4.8% very severe. The BDT was positive in 8.8% of the spirometries, with 11.2% only positive in volume, and 17.6% were only positive in percentage. It was observed that the patients with a BDT positive in percentage had a lower base forced expiry volume in the first second (1.66 L/sec vs.2.74 L/sec; P<.001), and a lower forced vital capacity (2.85 l vs.3.73 l; P<.001). The patients with a positive BDT in volume had a lower forced expiry volume in the first second (2.59 l/sec vs.2.62 l/sec; P<.001), and a higher forced vital capacity (3.89 l vs.3.58 l; P<.001).

CONCLUSIONS:

The baseline forced expiry volume in the first second and forced vital capacity have an influence in the positivity of the BDT. This circumstance should be assessed when establishing the positivity of the BDT
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Atenção Primária à Saúde / Espirometria / Broncodilatadores / Pneumopatias Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: SEMERGEN, Soc. Esp. Med. Rural Gen. (Ed. Impr.) Ano de publicação: 2019 Tipo de documento: Artigo Instituição/País de afiliação: Centro de Salud Sillería/España / Instituto de Ciencias de la Salud/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Atenção Primária à Saúde / Espirometria / Broncodilatadores / Pneumopatias Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: SEMERGEN, Soc. Esp. Med. Rural Gen. (Ed. Impr.) Ano de publicação: 2019 Tipo de documento: Artigo Instituição/País de afiliação: Centro de Salud Sillería/España / Instituto de Ciencias de la Salud/España
...