Rendimiento diagnóstico de la troponina de alta sensibilidad en el síndrome coronario agudo sin elevación del segmento ST / Diagnostic performance of high sensitive troponin in non-ST elevation acute coronary syndrome
Velilla Moliner, J; Gros Bañeres, B; Povar Marco, J; Santaló Bel, M; Ordoñez Llanos, J; Martín Martín, A; Temboury Ruiz, F.
Afiliação
  • Velilla Moliner, J; Hospital Miguel Servet. Servicio de Urgencias. Zaragoza. España
  • Gros Bañeres, B; Hospital Miguel Servet. Servicio de Urgencias. Zaragoza. España
  • Povar Marco, J; Hospital Miguel Servet. Servicio de Urgencias. Zaragoza. España
  • Santaló Bel, M; Hospital Sant Pau. Servicio de Críticos. Barcelona. España
  • Ordoñez Llanos, J; Universidad Autónoma. Hospital Sant Pau. Departamento de Bioquímica y Biología Molecular. Barcelona. España
  • Martín Martín, A; Hospital Severo Ochoa. Servicio de Urgencias. Leganés. España
  • Temboury Ruiz, F; Hospital Clínico. Servicio de Urgencias. Málaga. España
Med. intensiva (Madr., Ed. impr.) ; 44(2): 88-95, mar. 2020. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-188657
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Los objetivos del estudio son evaluar el rendimiento diagnóstico de la troponina cardiaca T de alta sensibilidad (TnTc-hs) en pacientes con sospecha de síndrome coronario agudo sin elevación del segmento ST (SCASEST), confirmar si permite acortar el tiempo hasta el diagnóstico y analizar las consecuencias clínicas derivadas de su utilización.

Método:

Se trata de un estudio observacional, longitudinal y prospectivo, realizado en 5 servicios de urgencias hospitalarias. Se incluyó de forma consecutiva a los pacientes que acudían por dolor torácico sospechoso de SCASEST. El manejo del paciente y el tratamiento aplicado siguieron los protocolos internos basados en las guías de consenso de la Sociedad Europea de Cardiología. Se realizaron determinaciones seriadas de Tnc convencional (4ªG) y de TnTc-hs.

Resultados:

Se incluyó en el estudio a 351 pacientes. El diagnóstico final de infarto agudo de miocardio (IAM) se estableció en 77 pacientes del total, angina inestable en 102 y 172 fueron pacientes diagnosticados como sin síndrome coronario agudo. Los valores de TnTc-hs estaban por encima del p99 en un alto número de pacientes sin IAM. En la determinación inicial del paciente, la sensibilidad diagnóstica de la TnTc-hs fue significativamente superior a la de la TnTc 4ªG (87,0 vs. 42,9%), lo que comportó un valor predictivo negativo del 95,1%.

Conclusiones:

La TnTc-hs mejora el rendimiento diagnóstico al compararla con el ensayo de Tnc convencional, acorta el tiempo hasta el diagnóstico y reconoce mayor número de pacientes con IAM más pequeños
ABSTRACT

Objective:

To assess the diagnostic performance of high-sensitivity troponin T (hs-TnT) in patients with suspected non-ST elevation acute coronary syndrome (NSTE-ACS); confirm whether it shortens the time to diagnosis; and analyze the clinical consequences derived from its use.

Method:

A prospective, longitudinal observational study was carried out in 5 emergency care departments. Patients seen for chest pain with suspected of NSTE-ACS were consecutively included. Patient care followed the internal protocols of the center, based on the consensus guidelines of the European Society of Cardiology. Serial conventional cardiac troponin (cTn) and hs-TnT determinations were made.

Results:

A total of 351 patients were included in the study. A final diagnosis of acute myocardial infarction (AMI) was established in 77 patients, with unstable angina in 102, and no acute coronary syndrome in 172 patients. The hs-TnT values were above percentile 99% in a large number of patients without AMI. In the initial determination, the diagnostic sensitivity of the hs-TnT was significantly greater than that of cTn (87.0% vs. 42.9%), which led to a negative predictive value of 95.1%.

Conclusions:

High-sensitivity troponin T improves diagnostic performance compared with conventional troponin assay, shortens the time to diagnosis, and identifies a larger number of patients with smaller myocardial infarctions
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Dor no Peito / Valor Preditivo dos Testes / Troponina T / Síndrome Coronariana Aguda / Infarto do Miocárdio sem Supradesnível do Segmento ST Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Med. intensiva (Madr., Ed. impr.) Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico/España / Hospital Miguel Servet/España / Hospital Sant Pau/España / Hospital Severo Ochoa/España / Universidad Autónoma/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Dor no Peito / Valor Preditivo dos Testes / Troponina T / Síndrome Coronariana Aguda / Infarto do Miocárdio sem Supradesnível do Segmento ST Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Med. intensiva (Madr., Ed. impr.) Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico/España / Hospital Miguel Servet/España / Hospital Sant Pau/España / Hospital Severo Ochoa/España / Universidad Autónoma/España
...