¿Es necesaria la realización de ecocardiograma en la valoración de hipertensión pulmonar previa a una criobiopsia transbronquial? / Transbronchial cryobiopsy, is essential to rule out pulmonary hypertension?
Gómez López, A; García Luján, R; Villena Garrido, V; Valipour, A; García Quero, C; Miguel Poch, E De.
Afiliação
  • Gómez López, A; Hospital Universitario 12 de Octubre. Servicios de Neumología. Madrid. España
  • García Luján, R; Hospital Universitario 12 de Octubre. Servicios de Neumología. Madrid. España
  • Villena Garrido, V; Hospital Universitario 12 de Octubre. Servicios de Neumología. Madrid. España
  • Valipour, A; Ludwig-Boltzmann-Institute for COPD and Respiratory. Vienna. Austria
  • García Quero, C; Hospital Universitario La Paz. Madrid. España
  • Miguel Poch, E De; Hospital Universitario 12 de Octubre. Servicios de Neumología. Madrid. España
Rev. patol. respir ; 23(1): 3-8, ene.-mar. 2020. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-191887
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

INTRODUCCIÓN:

El objetivo de nuestro estudio fue valorar la posibilidad de diagnosticar la Hipertensión Pulmonar (HP) mediante signos en la tomografía computarizada (TC), en pacientes con EPID que van a ser sometidos a criobiopsia transbronquial (CBxTb) sin necesidad de realizar ecocardiograma transtoracico (EcoC) sistemático y si la existencia de HP en TC influye de manera relevante en el riesgo de complicaciones de sangrado y en las demoras de realización de la técnica. MATERIAL Y

MÉTODOS:

Estudio prospectivo de casos controles de todos los pacientes en los que se realizó CBxTb en un período de 20 meses. Los controles fueron los pacientes en los que se realizó CBxTb con EcoC previa protocolizada y los casos los pacientes en los que se realizó EcoC pre CBxTb sólo sin había signos de HP en la TC. Analizamos la correlación entre los datos de HP de la TC y EcoC, las complicaciones por sangrado y la demora al procedimiento entre los grupos.

RESULTADOS:

Se han realizado 40 CBxTb. Se incluyeron 16 controles; 12 (75%) sin signos de HP en la TC con una especificidad de ésta en relación al EcoC del 85%, sensibilidad 71% y VPN 82%. Se incluyeron 24 casos y, tras los hallazgos de la TC, sólo se solicitó EcoC preCBxTb a 4 pacientes, de los que 3 resultaron falsos positivos. No hubo diferencias entre grupo de controles y casos en cuanto al sangrado (18,7% vs. 16,7%; p= 0,54) pero si en la demora diagnóstica (62 vs. 37; p= 0,03).

CONCLUSIÓN:

En nuestra serie de pacientes con EPID y CBxTb consideramos indicada la realización de EcoC sólo en casos con signos de HP en la TC, permitiendo acortar la demora diagnóstica sin aumento de sangrados
ABSTRACT

INTRODUCTION:

Our objective was to assess whether the performance of EcoC only in those patients in which the caliper measurement of the PA on CT suggested the existence ofPAH, relevant influence on the risk of bleeding complications and delays CbxTb conducting. MATERIAL AND

METHODS:

It has been conducted prospective, case-control, of all patients who underwent CbxTb in our unit over a period of 20 months. Defining control group those patients who EcoC was done protocolised, before CbxTb, and cases all patients who EcoC was made only in cases where there were signs of PAH in CT. We analized the correlation in HP diagnosis signs between CT and EcoC data, risk of bleeding and delays in the procedure.

RESULTS:

We were performed 40 patients. In the control group include 16 patients, CTdetected no signs of HP in 12 (75%) cases, with a specificity of 85%, sensitivity of 71% and negative predictive value of 82%. In our cases group, we include 24 patients, and EcoC was only made before the procedure in 4 cases, 3 of them false positives. No differences in bleeding was found between control and cases groups (18.7% vs. 16.7%; p= 0.54) but for the delays in the procedure was lower in the cases group (62 days vs. 37; p= 0.03) .Conclusion. In our study with interstitial lung disease and CbxTb we conclude that EcoC was indicated only in the cases with PH findings on CT reducing the delays in the procedure without bleeding rate increase
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Biópsia / Doenças Pulmonares Intersticiais / Criocirurgia / Criobiologia / Hipertensão Pulmonar Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. patol. respir Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario 12 de Octubre/España / Hospital Universitario La Paz/España / Ludwig-Boltzmann-Institute for COPD and Respiratory/Austria
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Biópsia / Doenças Pulmonares Intersticiais / Criocirurgia / Criobiologia / Hipertensão Pulmonar Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. patol. respir Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario 12 de Octubre/España / Hospital Universitario La Paz/España / Ludwig-Boltzmann-Institute for COPD and Respiratory/Austria
...