Your browser doesn't support javascript.
loading
El ocaso del modelo lineal sin umbral / The downfall of the linear non-threshold model
Suárez Fernández, JP.
Afiliação
  • Suárez Fernández, JP; Hospital Universitario Central de Asturias. Servicio de Medicina Nuclear. Oviedo. España
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 39(5): 303-315, sept.-oct. 2020. graf
Artigo em Espanhol | IBECS | ID: ibc-198292
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
El modelo lineal sin umbral (MLSU) es una función dosis-respuesta teórica obtenida de extrapolar los efectos tardíos debidos a la exposición a altas dosis de radiación ionizante al rango de las bajas dosis, pero existen grandes incertidumbres respecto a su validez. La aceptación del MLSU como modelo probabilístico preponderante ha sobrevivido hasta nuestros días y constituye la piedra angular que sostiene las políticas actuales de protección radiológica. En las últimas décadas, los avances en biología molecular y evolutiva, en la inmunología del cáncer, así como los resultados obtenidos de los estudios epidemiológicos y en modelos animales, han puesto en entredicho la fiabilidad del MLSU en favor de otras alternativas, como la teoría hormética. A la vista de las evidencias, se hace necesario un debate entre las sociedades científicas implicadas y los organismos reguladores que aborde una redefinición de las bases de la protección radiológica, cuya importancia sería capital en el ámbito médico
ABSTRACT
The linear non-threshold model (LNTM) is a theoretical dose-response function as a result of extrapolating the late effects of high-dose exposure to ionizing radiation to the low-dose range, but there is great uncertainty about its validity. The acceptance of LNTM as the dominant probabilistic model have survived to the present day and it is actually the cornerstone of current radiation protection policies. In the last decades, advances in molecular and evolutive biology, cancer immunology, and many epidemiological and animal studies have cast serious doubts about the reliability of the NLTM, as well as suggesting alternative models, like the hormetic theory. Considering the given evidences, a discussion between the involved scientific societies and the regulatory commissions is promtly required in order to to reach a redefiniton of theradiation protection basis, as it would be specially crucial in the medical field
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Lesões por Radiação / Proteção Radiológica / Radiobiologia / Relação Dose-Resposta à Radiação / 51569 / Hormese / Carcinogênese Limite: Humanos Idioma: Espanhol Revista: Rev. esp. med. nucl. imagen mol. (Ed. impr.) Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Central de Asturias/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Lesões por Radiação / Proteção Radiológica / Radiobiologia / Relação Dose-Resposta à Radiação / 51569 / Hormese / Carcinogênese Limite: Humanos Idioma: Espanhol Revista: Rev. esp. med. nucl. imagen mol. (Ed. impr.) Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Central de Asturias/España
...