RESUMEN
El colgajo interóseo posterior de pedículo distal se basa en el arco anastomótico dorsal formado por las arterias interóseas anterior y posterior. Cuando dicha arcada está interrumpida, no es posible elevar un colgajo interóseo posterior de pedículo distal. Presentamos un colgajo de perforante interósea posterior diseñado en hélice, disponible en ausencia de la arcada vascular dorsal y útil en la cobertura de tercio distal del antebrazo, carpo y mano. Detallamos la técnica quirúrgica, sus aplicaciones, ventajas e inconvenientes y analizamos el empleo de este tipo de colgajo en diferentes casos. Presentamos el caso de un paciente con exposición de material de osteosíntesis en tercio distal de radio y trombosis de las anastomosis de revascularización tras sufrir aplastamiento severo de su miembro superior izquierdo; el examen con Doppler reveló ausencia de flujo reverso en la arteria interósea posterior. Se practicó un colgajo en hélice de perforanteinterósea posterior para cubrir el nuevo by-pass y la osteosíntesis. También otro paciente que tras un accidente de automóvil sufrió fracturas cerradas de cúbito y radio en su miembro superior izquierdo. La columna radial del carpo presentaba una severa lesión por aplastamiento. Tras las osteosíntesis, se practicó un colgajo en hélice de perforanteinterósea posterior para cobertura de la cara dorso-radial del carpo. En los casos clínicos presentados el colgajo en hélice de perforanteinterósea posterior proporcionó excelente cobertura del carpo y de la mano con escasa morbilidad de la zona donante. El colgajo en hélice de perforante interósea posterior se presenta como una opción versátil y segura para la cobertura del tercio distal de miembro superior, pudiendo ser elevado en ausencia de flujo reverso y sin sacrificio de la arteria interósea posterior (AU)
ABSTRACT
The distally-based posterior interosseous flap is a versatile and useful technique in upper limb reconstruction. This flap is based on the integrity of the dorsal carpal anastomosis between the anterior interosseous artery and the posterior interosseous artery. Hence, when the dorsal carpal anastomosisis not available, it is not possible to perform a distally-based posteriorinterosseous flap. We report a propeller perforator flap proximally based, available without the dorsal carpal supply, and useful for the coverage of the distal third of the forearm, wrist and hand. We report the surgical technique, its applications, advantages and disadvantages and review the use o this flap in different clinical cases. A patient suffered a severe crush injury of their left upper limb. He presented osteosynthesis plate exposure in the radius and thrombosis of there vascularization anastomosis. The absence of reverse flow in the posteriorinterosseous artery was proven with Doppler Ultrasounds. A propellerinterosseous posterior perforator flap was performed to cover a new by-pass and the osteosynthesis plate. Another patient suffered an automobile accident. He presented closed fractures of radius and ulna of their left upper limb. The radial column of carpus suffered a severe crush injury. After the osteosynthesis, a propellerinterosseous posterior perforator flap was performed. The flap provided appropriate coverage of the dorso-radial aspect of the wrist andhand. In our clinical cases the propeller interosseous posterior perforator flap provided excellent coverage of the carpus and hand with low donorsite morbidity. Propeller interosseous posterior perforator flap provide a versatile and reliable coverage option in upper limb reconstruction, available in absence of the dorsal carpal anastomosis and without sacrifice of the interosseous posterior artery (AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Retalhos Cirúrgicos / Procedimentos de Cirurgia Plástica / Traumatismos do Antebraço / Traumatismos da Mão Limite: Humanos / Masculino Idioma: Espanhol Revista: Cir. plást. ibero-latinoam Ano de publicação: 2009 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen de la Arrixaca/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Retalhos Cirúrgicos / Procedimentos de Cirurgia Plástica / Traumatismos do Antebraço / Traumatismos da Mão Limite: Humanos / Masculino Idioma: Espanhol Revista: Cir. plást. ibero-latinoam Ano de publicação: 2009 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen de la Arrixaca/España
...