Your browser doesn't support javascript.
loading
Measurement of gastric emptying of solid meal using scitigraphy with 99mTccoloidal sulfur and breath test with 14C-acid octanoic
Siqueira, Amal Hachouch; Cardoso, Valbert Nascimento; Coelho, Luiz Gonzaga; Junqueira, Roberto Gonçalves; Simal, Carlos Jorge Rodrigues; Marinho, Frederico Passos; Correia, M. M; Soares, Marcela Penna; Chausson, Yvon.
Afiliação
  • Siqueira, Amal Hachouch; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Cardoso, Valbert Nascimento; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Coelho, Luiz Gonzaga; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Junqueira, Roberto Gonçalves; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Simal, Carlos Jorge Rodrigues; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Marinho, Frederico Passos; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Correia, M. M; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Soares, Marcela Penna; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
  • Chausson, Yvon; Federal University of Minas Gerais. Faculty of Medicine. Belo Horizonte. BR
GED gastroenterol. endosc. dig ; 19(2): 79-83, mar.-abr. 2000. tab, graf
Artigo em Inglês | LILACS | ID: lil-312488
Biblioteca responsável: BR9.1
RESUMO
The gastric emptying rate of solids was measures in 33 volunteers (19 female 14 male, mean age 38.2 (24-74) years) by scintigraphy and 14-C-octanoic acid breattest. Eleven participants were normal controls, 11 had functional dyspepsia, 5 patients were diabetic and 6 patients had pyloric stenosis due to peptic ulcer.

Methods:

The test meal consisted of an omelet labeled with 99mTc-sulfur colloid and 14C-octanoic acid for scitigraphy and breath tes, respectively. Radioscintigraphic scans were obtained every 15 min for a period of 150 min and breath samples were taken every 15 min for a period of 4 hours. Reults the half gastric emptying time (t1/2) and lag phase (tlag) in diabetica and dyspeptic volunteers measured by scintigraphy and breath tes showed higher values than in controls. Two out 6 patients with pyloric stenosis showed gastric emptying rate delayed when compared with controls. There was a positive and significant (p<0.0001) correlation between the t1/2 determined by scintigraphy and breath test.

Conclusions:

14C-octanoic acid breath test is a reliable and sensitive method that can be used as an alternative procedure to measure gastric emptying rat of solids
Assuntos
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Testes Respiratórios / Cintilografia / Partículas Coloidais / Esvaziamento Gástrico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: GED gastroenterol. endosc. dig Assunto da revista: Gastroenterologia Ano de publicação: 2000 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Minas Gerais/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Testes Respiratórios / Cintilografia / Partículas Coloidais / Esvaziamento Gástrico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: GED gastroenterol. endosc. dig Assunto da revista: Gastroenterologia Ano de publicação: 2000 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Minas Gerais/BR
...