Your browser doesn't support javascript.
loading
Utilidad de las imágenes centelleográficas con 111In. CYT-103 en el diagnóstico de recurrencia del cáncer de colon y recto / Usefulness of scintigraphy images with 111In-CYT-103 in the diagnosis of colonic and rectal recurrence
García-Fernández, Rosalba; Luna-Pérez, Pedro; Hernández-Hernández, Dulce Maria; Iwasaki-Otake, Laura; Pichardo-Romero, Pablo; Rodríguez-Ramirez, Saúl.
Afiliação
  • García-Fernández, Rosalba; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. MX
  • Luna-Pérez, Pedro; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. MX
  • Hernández-Hernández, Dulce Maria; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. MX
  • Iwasaki-Otake, Laura; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. MX
  • Pichardo-Romero, Pablo; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. MX
  • Rodríguez-Ramirez, Saúl; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. MX
Gac. méd. Méx ; 138(2): 139-144, mar.-abr. 2002.
Artigo em Espanhol | LILACS | ID: lil-333665
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

To determine the effectiveness of radioimmunoscintigraphy (RIC) with 111In-CYT-103 in detecting the extension of malignant disease in patients surgically treated for colorectal adenocarcinoma under suspicion of recurrence in comparison to CT scan (computed tomography) and exploratory laparotomy.

DESIGN:

Prospective and observational study. MATERIAL AND

METHODS:

A total of 26 patients under suspicion of recurrence, with a total of 31 lesions. All the patients had performed the following studies with GT, RIC with 111In-CYT-103, exploratory laparotomy and histopathology.

RESULTS:

A sensitivity of 96.8, and specificity of 77.8, and accuracy of 92 were found for the RIC. CT scan had a sensitivity, specificity and accuracy of 71.5, 88.8, and 75.7, respectively in extrahepatic lesions. When both methods are combined, results shows an increment in sensitivity. Hepatic lesions were present in 50 of the patients; a sensitivity of 85, a specificity of 92, and accuracy of 89 for RIC and sensitivity, specificity and accuracy of 92 for the CT.

CONCLUSION:

The results of clinical studies with 111In-CYT-103 in detecting the occurrence of colorectal carcinoma provided additional information, making this method a valuable complementary test that contributes to patient management.
Assuntos
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Oligopeptídeos / Neoplasias Colorretais / Adenocarcinoma / Ácido Pentético / Anticorpos Monoclonais / Recidiva Local de Neoplasia Tipo de estudo: Estudo diagnóstico / Estudo observacional Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Gac. méd. Méx Assunto da revista: Medicina Ano de publicação: 2002 Tipo de documento: Artigo País de afiliação: México Instituição/País de afiliação: Instituto Mexicano del Seguro Social/MX
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Oligopeptídeos / Neoplasias Colorretais / Adenocarcinoma / Ácido Pentético / Anticorpos Monoclonais / Recidiva Local de Neoplasia Tipo de estudo: Estudo diagnóstico / Estudo observacional Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Gac. méd. Méx Assunto da revista: Medicina Ano de publicação: 2002 Tipo de documento: Artigo País de afiliação: México Instituição/País de afiliação: Instituto Mexicano del Seguro Social/MX
...