Your browser doesn't support javascript.
loading
Intensidade de ruído em hospital de 222 leitos na 18ª Regional de Saúde - PR / Noise level in a 222 bed hospital in the 18th health region - PR
Otenio, Marcelo Henrique; Cremer, Edivaldo; Claro, Elis Marina Turini.
Afiliação
  • Otenio, Marcelo Henrique; s.af
  • Cremer, Edivaldo; s.af
  • Claro, Elis Marina Turini; s.af
Rev. bras. otorrinolaringol ; 73(2): 245-250, mar.-abr. 2007. graf
Artigo em Português | LILACS | ID: lil-453365
Biblioteca responsável: BR1.1
RESUMO
A poluição sonora ambiental torna-se hoje onipresente e beira o intolerável. Nos hospitais, os avanços tecnológicos trazem, como conseqüência, níveis de ruído potencialmente danosos. Muito do ruído no hospital provém mais de dentro, do que de fora desse ambiente, sendo as principais causas de ruído em Unidade de Terapia Intensiva, por exemplo, os equipamentos e a conversação entre a equipe hospitalar. O objetivo deste trabalho foi avaliar o nível de ruído nos diversos ambientes hospitalares, em Hospital de 222 leitos na 18ª RS de Saúde - PR.

MATERIAIS E MÉTODOS:

Conduziu-se, em março de 2005 no período de 24 horas, em dez setores. Forma de Estudo Aferição do nível de ruído ambiental utilizando um Decibelímetro modelo 1350.

RESULTADOS:

O nível de ruído encontrado em nosso estudo apresentou média total de 63,7 dB(A), que excede os valores máximos permitidos de 45 dB recomendados pela Associação Brasileira de Normas Técnicas (1987).

CONCLUSÃO:

Nos setores analisados, o nível de ruído encontrado neste está consideravelmente acima do recomendado. A equipe hospitalar deve estar consciente do ruído e dos efeitos deste, para que possa atuar de maneira mais efetiva na redução da poluição sonora, beneficiando assim a função laborativa dos profissionais e recuperação dos pacientes.
ABSTRACT
Environment noise pollution is common place today, at intolerable levels. In hospitals, technological developments have, as a consequence, potentially harmful noise levels. Much of the hospital noise comes from inside, rather than outside, and the major source of such noise is the Intensive Care Unit, for example equipment and hospital staff talk. Our goal with the present study was to investigate the noise level present in the different hospital environments, within a 222 bed hospital located at the 18th health zone, PR. MATERIALS AND

METHODS:

The study was carried out in March, 2005, during a period of 24 hours, in tem different sectors. CASE STUDY We checked environmental sound level by means of a model 1350 decibel meter.

RESULTS:

The sound level found in our study was of 63.7 dB(A) in average, which exceeds the 45 dB recommended by the Brazilian Association of Technical Standards (1987).

CONCLUSION:

In the analyzed sectors, the sound level was considerably above the recommended maximum. The hospital staff should be aware of this noise level and its effects, so that they may act in a more efficient way in order to reduce this noise pollution; thus benefiting the professionals and patient recovery.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Unidades Hospitalares / Ruído / Ruído Ocupacional Tipo de estudo: Guia de prática clínica Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. otorrinolaringol Assunto da revista: Otorrinolaringologia Ano de publicação: 2007 Tipo de documento: Artigo
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Unidades Hospitalares / Ruído / Ruído Ocupacional Tipo de estudo: Guia de prática clínica Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. otorrinolaringol Assunto da revista: Otorrinolaringologia Ano de publicação: 2007 Tipo de documento: Artigo
...