Your browser doesn't support javascript.
loading
Mudança de conduta cirúrgica motivada pela ecocardiografia transesofágica intraoperatória / Changes in surgical conduct due to the results of intraoperative transesophageal echocardiography / Cambio de conducta quirúrgica motivada por la ecocardiografía transesofágica intraoperatoria
Silva, Alexander Alves da; Silva, Enis Donizete; Segurado, Arthur Vitor Rosenti; Kimachi, Pedro Paulo; Simões, Claudia Marques.
Afiliação
  • Silva, Alexander Alves da; São Paulo Serviços Médicos de Anestesia. BR
  • Silva, Enis Donizete; São Paulo Serviços Médicos de Anestesia. BR
  • Segurado, Arthur Vitor Rosenti; São Paulo Serviços Médicos de Anestesia. BR
  • Kimachi, Pedro Paulo; São Paulo Serviços Médicos de Anestesia. BR
  • Simões, Claudia Marques; São Paulo Serviços Médicos de Anestesia. BR
Rev. bras. anestesiol ; 60(2): 192-197, mar.-abr. 2010. ilus
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-552048
Biblioteca responsável: BR1.1
RESUMO
JUSTIFICATIVA E

OBJETIVOS:

A utilização da ecocardiografia transesofágica (ETE) é de valor indiscutível em procedimentos cirúrgicos como valvoplastias, cirurgias da aorta torácica e correções de cardiopatias congênitas. Entre as grandes vantagens da utilização da ETE destacam-se a pouca invasividade do método e a capacidade de agregar informações que podem alterar o curso da cirurgia. O objetivo deste relato foi apresentar um caso onde a condução cirúrgica da paciente foi alterada em decorrência de novos diagnósticos feitos pela ecocardiografia transesofágica no intraoperatório e ressaltar a importância da utilização do eco transesofágico em cirurgias para correção de cardiopatia congênita. RELATO DO CASO Paciente do sexo feminino, 28 anos, ASA II, com história de dispneia progressiva aos médios e depois pequenos esforços, veio encaminhada de outro serviço para correção cirúrgica eletiva de estenose da valva pulmonar diagnosticada pela ecocardiografia transtorácica. A ecocardiografia transesofágica intraoperatória evidenciou presença do forâmen oval patente, estenose infundibular da via de saída do ventrículo direito e comunicação interventricular (CIV) perimembranosa subaórtica medindo 0,4 cm com fluxo da esquerda para direita. Após a entrada da paciente em circulação extracorpórea foram confirmados os diagnósticos mencionados acima, e a cirurgia realizada incluiu o fechamento do forâmen oval e da CIV e a ressecção da estenose do infundíbulo. Não houve intercorrências cirúrgicas, e a paciente foi encaminhada intubada para a unidade de terapia intensiva.

CONCLUSÕES:

A ecocardiografia transesofágica em pacientes submetidos à correção de cardiopatia congênita é de extrema utilidade, pois, além de ajudar no manejo hemodinâmico do paciente, pode trazer novas informações, capazes de melhorar o resultado final da cirurgia.
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Transesophageal echocardiography (TEE) is extremely useful in surgeries like valvuloplasty, of the thoracic aorta, and correction of congenital cardiopathies. The low degree of invasiveness and the capacity to aggregate information that can change the course of the surgery are among the advantages of TEE. The objective of this report was to present a case in which the surgical conduct was changed due to a new diagnosis provided by intraoperative transesophageal echocardiography, and to emphasize the importance of using the transesophageal echo in surgeries to correct congenital cardiopathies. CASE REPORT A 28-year old female, ASA II, with a history of dyspnea progressing from medium to small efforts was referred by another department for elective surgical correction of stenosis of the pulmonary valve diagnosed by transthoracic echocardiography. Intraoperative transesophageal echocardiography showed patent foramen ovale, infundibular stenosis of the right ventricular outlet, and perimembranous subaortic interventricular communication (IVC) of 0.4 cm with left to right shunt. After beginning ECC, the above mentioned diagnoses were confirmed and the surgery included closure of the foramen ovale and IVC, and resection of the infundibular stenosis. Intraoperative intercurrences were not observed and the patient was intubated when she was transferred to the intensive care unit.

CONCLUSIONS:

Transesophageal echocardiography is extremely useful in patients undergoing surgical correction of congenital cardiopathies because, besides helping the hemodynamic management, it can provide new information capable of improving the final result of the surgery.
RESUMEN
JUSTIFICATIVA Y

OBJETIVOS:

La utilización de la ecocardiografía transesofágica (ETE) es de un valor indiscutible en los procedimientos quirúrgicos como valvuloplastias, cirugías de la aorta torácica y correcciones de cardiopatías congénitas. Entre las grandes ventajas de la utilización de la ETE se destacan la poca invasión del método y la capacidad de agregar informaciones que pueden alterar el curso de la cirugía. El objetivo de este relato fue presentar un caso donde la conducción quirúrgica de la paciente fue alterada como consecuencia de nuevos diagnósticos detectados por la ecocardiografía transesofágica en el intraoperatorio y resaltar la importancia de la utilización del eco transesofágico en las cirugías para la corrección de la cardiopatía congénita. RELATO DEL CASO Paciente del sexo femenino, 28 años, ASA II, con historial de disnea progresiva a los medios y después de pequeños esfuerzos. Llegó remitida de otro servicio para la corrección quirúrgica electiva de estenosis de la valva pulmonar diagnosticada por la ecocardiografía transtorácica. La ecocardiografía transesofágica intraoperatoria arrojó la presencia del foramen oval patente, estenosis infundibular de la vía de salida del ventrículo derecho y comunicación interventricular (CIV) perimembranosa subaórtica, midiendo 0,4 cm con flujo de la izquierda hacia la derecha. Después que la paciente entró en circulación extracorpórea, fueron confirmados los diagnósticos mencionados anteriormente y la cirugía realizada incluye el cierre del foramen oval y de la CIV, y la resección de la estenosis del infundíbulo. No se registraron intercurrencias quirúrgicas, y la paciente fue derivada, ya intubada, a la unidad de cuidados intensivos.

CONCLUSIONES:

La ecocardiografía transesofágica en pacientes sometidos a la corrección de cardiopatía congénita es de extrema utilidad, porque además de ayudar en el manejo hemodinámico del paciente, puede traer nuevas informaciones, capaces de...
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ecocardiografia Transesofagiana / Cardiopatias Congênitas / Cuidados Intraoperatórios Limite: Adulto / Feminino / Humanos Idioma: Inglês / Espanhol / Português Revista: Rev. bras. anestesiol Assunto da revista: Anestesiologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Paulo Serviços Médicos de Anestesia/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ecocardiografia Transesofagiana / Cardiopatias Congênitas / Cuidados Intraoperatórios Limite: Adulto / Feminino / Humanos Idioma: Inglês / Espanhol / Português Revista: Rev. bras. anestesiol Assunto da revista: Anestesiologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Paulo Serviços Médicos de Anestesia/BR
...