Your browser doesn't support javascript.
loading
Utilización del ensayo Cobas Amplicor Monitor HIV-1 en el diagnóstico temprano de la infección por HIV en pediatría / Utility of the Cobas Amplicor Monitor HIV-1 assay in the early diagnosis of HIV pediatric infection
Cañizal, Ana María; González, Fernanda; Fernández Giuliano, Silvina; Zapiola, Inés; Bouzas, María Belén.
Afiliação
  • Cañizal, Ana María; Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz. Buenos Aires. AR
  • González, Fernanda; Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz. Buenos Aires. AR
  • Fernández Giuliano, Silvina; Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz. Buenos Aires. AR
  • Zapiola, Inés; Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz. Buenos Aires. AR
  • Bouzas, María Belén; Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz. Buenos Aires. AR
Actual. SIDA ; 18(67): 18-24, mar. 2010. tab
Artigo em Espanhol | LILACS | ID: lil-566745
Biblioteca responsável: AR392.1
RESUMEN
Dado que en Argentina el ensayo de HIV RNA cualitativo (QL) ha sido discontinuado, el objetivo del presente trabajo fue evaluar el ensayo de RNA cuantitativo (CV) COBAS AMPLICOR Monitor HIV-1 para su posible incorporación en el diagnóstico pediátrico de infección por HIV en niños expuestos perinatalmente y estimar la concordancia con QL. Fueron incluidas 214 muestras (134 pacientes), 174 muestras de 113 pacientes negativos y 40 correspondientes a 21 pacientes positivos con diagnóstico definitivo. Todas las muestras fueron estudiadas para CV usando el procedimiento estándar (ST, rango 400-750.000 copias/ml) y aquellas por debajo del rango lineal se procesaron por el método ultrasensible (US, rango 50-100.000 copias/ml). El ensayo de CV fue comparado con el de QL en un subgrupo de 93 muestras (78 negativas y 15 positivas). Las 174 muestras pertenecientes a niños HIV negativos tuvieron CV indetectables y entre las 40 muestras pertenecientes a niños HIV positivos, 37 evidenciaron CV detectables (2-5,88 log 10). En 4/37 muestras se detectaron CV entre 165-575 copias/ml, que en muestras posteriores evidenciaron altos valores de CV. El 83,7 % de las muestras resultaron con CV> a 4 log 10. La sensibilidad de la CV según grupo etario fue de 77,7 % < 15 días, 93,3 % entre 15-45 días y la especificidad general del 100 %. La concordancia global entre QL y CV fue del 97,8 %, siendo el ensayo de CV más sensible. Nuestros resultados sugieren la inclusión del ensayo COBAS AMPLICOR en el algoritmo diagnóstico, no presentando resultados falsos positivos.
ABSTRACT
Since in Argentina qualitative dHIV RNA (QL) test, has been discontinued, the objective of this study was to evaluate the quantitative RNA (VL) COBAS AMPLICOR monitor HIV-1, for its possible inclusion in the paediatric diagnosis of HIV infection and to evaluate the concordance between both assays. In this study 214 samples corresponding to 134 patients were included, 174 and 40 specimens from 113 HIV-negative and 21 HIV-positive patients respectively. All samples were studied for VL using the standard procedure (ST, range 400-750.000 copies/mal), and those below the linear range were further tested by the ultrasensitive method (US, range 50-100.000 copies/ml) QL and VL assays were compared among a subgroup of 93 samples (78 negative and 15 positive). All 174 samples from HIV negative children had undetectable VL. 37/40 samples from HIV-positive had detectable VL (2-5,88 log 10) 4/37 specimens had VL between 165-575 copies/ml, later samples from the corresponding patients showed high VL. 83,7 % of the samples had VL> 4 log 10. The sensitivities found were 77,7 % and 93,3 % among infants < 15 days and between 15-45 days of aged respectively. The general specificity of the COBAS AMPLICOR was 100 %. The concordance between QL and VL eas 97,8 %, showing the later one better sensitivity. Our results support the inclusion of COBAS AMPLICOR in the diagnosis algorithm, not showing false positive results.
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Avaliação de Processos e Resultados em Cuidados de Saúde / RNA / Ácidos Nucleicos / HIV / Carga Viral / Técnicas e Procedimentos Diagnósticos / Terapia Antirretroviral de Alta Atividade / Técnicas de Amplificação de Ácido Nucleico / Diagnóstico Precoce Tipo de estudo: Estudo diagnóstico / Pesquisa qualitativa / Estudo de rastreamento Limite: Criança / Humanos Idioma: Espanhol Revista: Actual. SIDA Assunto da revista: Medicina / SINDROIMUNE IMUN ADQUIRIDAUIRIDAUIRIDA Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz/AR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Avaliação de Processos e Resultados em Cuidados de Saúde / RNA / Ácidos Nucleicos / HIV / Carga Viral / Técnicas e Procedimentos Diagnósticos / Terapia Antirretroviral de Alta Atividade / Técnicas de Amplificação de Ácido Nucleico / Diagnóstico Precoce Tipo de estudo: Estudo diagnóstico / Pesquisa qualitativa / Estudo de rastreamento Limite: Criança / Humanos Idioma: Espanhol Revista: Actual. SIDA Assunto da revista: Medicina / SINDROIMUNE IMUN ADQUIRIDAUIRIDAUIRIDA Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital de Enfermedades Infecciosas Dr. Francisco Javier Muñiz/AR
...