Your browser doesn't support javascript.
loading
Emprego experimental da placa de compósito poli-hidroxibutirado/hidroxiapatita na fixação femoral em gatos / Experimental employment of polyhydroxybutyrate/hydroxyapatite composite plates in femoral fixation in cats
Alves, E. G. L; Rezende, C. M. F; Oliveira, H. P; Borges, N. F; Mantovani, P. F; Rosado, I. R.
Afiliação
  • Alves, E. G. L; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Rezende, C. M. F; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Oliveira, H. P; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Borges, N. F; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Mantovani, P. F; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Rosado, I. R; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
Arq. bras. med. vet. zootec ; 62(5): 1128-1134, out. 2010. ilus
Artigo em Português | LILACS | ID: lil-570471
Biblioteca responsável: BR68.1
RESUMO
Avaliou-se o compósito de poli-hidroxibutirado (PHB) 70 por cento e hidroxiapatita (HA) 30 por cento na forma de placas para fixação óssea em gatos. Foram usadas placas do compósito com 60mm de comprimento por 10mm de largura e espessura variando de 3mm no centro a 5mm nas extremidades, com seis orifícios. A placa do compósito foi empregada na fixação de osteotomia de fêmur em quatro gatos, totalizando seis intervenções. Verificou-se a ruptura de cinco placas (83,3 por cento) até o quarto dia e de uma placa (16,7 por cento) aos 21 dias, quando se observou um calo ósseo exuberante. O resultado da implantação da placa no gato mostrou que o compósito não possui resistência suficiente para ser empregado como placas de fixação de fêmur em gatos.
ABSTRACT
The composite of polyhydroxybutyrate (PHB) 70 percent and hydroxyapatite (HA) 30 percent was evaluated as plate for bone fixation in cats. The employed composite plates presented six orifices and measured 60 x 10mm, length and width, respectively, with thickness ranging from 3 to 5mm according to the region. The composite plate was used in the fixation of femoral osteotomy in four cats, in a total of six interventions. There were ruptures in five plates (83.3 percent) until day 4 and in one plate (16.7 percent) on the day 21, when it was possible to observe an exuberant osseous callus. The result of the plate deployment in the cat showed that the composite does not have sufficient strength to be used as plate of femoral fixation in cats.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Materiais Biocompatíveis / Fixação de Fratura Aspecto: Determinantes sociais da saúde Limite: Animais Idioma: Português Revista: Arq. bras. med. vet. zootec Assunto da revista: Medicina Veterinária Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Materiais Biocompatíveis / Fixação de Fratura Aspecto: Determinantes sociais da saúde Limite: Animais Idioma: Português Revista: Arq. bras. med. vet. zootec Assunto da revista: Medicina Veterinária Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR
...