Estudo dos limiares de audibilidade nas altas frequências em trabalhadores da área odontológica / A study of the high-frequency hearing thresholds of dentistry professionals
Lopes, Andréa Cintra; Melo, Ana Dolores Passarelli de; Santos, Cibele Carmelo.
Afiliação
  • Lopes, Andréa Cintra; s.af
  • Melo, Ana Dolores Passarelli de; Faculdade de Odontologia de Bauru. Bauru. BR
  • Santos, Cibele Carmelo; Faculdade de Odontologia de Bauru. Bauru. BR
Int. arch. otorhinolaryngol. (Impr.) ; 16(2): 226-231, abr.-jun. 2012. graf
Artigo em Português | LILACS | ID: lil-641633
Biblioteca responsável: BR66.1
RESUMO

Introdução:

Na prática odontológica, o Cirurgião-Dentista está sujeito aos efeitos nocivos provocados por diversos agentes, como pelo ruído emitido por seus instrumentos de trabalho. Em 1959, a American Dental Association recomendava avaliações audiométricas periódicas e uso de proteção auditiva. São necessárias maiores informações sobre o comportamento auditivo dessa população Cirurgiões-Dentistas, Auxiliares e Protéticos para se propor medidas de prevenção e tratamento precoce.

Objetivo:

Investigar os limiares de audibilidade em Cirurgiões-Dentistas, Auxiliares e Protéticos.

Método:

Forma de estudo Estudo Clínico.Participaram 108 profissionais, sendo 44 Cirurgiões-Dentistas (GI), 36 Auxiliares (G II) e 28 Protéticos (GIII). Foram realizadas entrevista específica, meatoscopia, audiometria tonal convencional e de altas frequências, logoaudiometria, imitanciometria.

Resultados:

A comparação entre as médias dos limiares evidenciaram piora com o aumento da frequência para os 3 grupos testados; para a média tritonal de 500 a 2000Hz, e 3000 a 6000 Hz, o GIII apresentou os piores limiares, já para a média das altas frequências (9000 a 16.000Hz) o GII apresentou os piores limiares.

Conclusão:

A avaliação audiológica convencional não identificou exames alterados para os três grupos testados, no entanto, o exame da avaliação audiológica complementar como a audiometria de altas frequências indicou maior sensibilidade na detecção precoce de alterações auditivas uma vez que a perda auditiva dessa população acomete as frequências que não são testadas nos exames convencionais. Dessa maneira enfatizamos nesse trabalho a necessidade de inserir na rotina de exames a audiometria de altas frequências juntamente com os outros exames audiológicos...
ABSTRACT

Introduction:

In the dentistry practice, dentists are exposed to harmful effects caused by several factors, such as the noise produced by their work instruments. In 1959, the American Dental Association recommended periodical hearing assessments and the use of ear protectors. Aquiring more information regarding dentists', dental nurses', and prosthodontists' hearing abilities is necessary to propose prevention measures and early treatment strategies.

Objective:

To investigate the auditory thresholds of dentists, dental nurses, and prosthodontists.

Method:

In this clinical and experimental study, 44 dentists (Group I; GI), 36 dental nurses (Group II; GII), and 28 prosthodontists (Group III; GIII) were included, , with a total of 108 professionals. The procedures that were performed included a specific interview, ear canal inspection, conventional and high-frequency threshold audiometry, a speech reception threshold test, and an acoustic impedance test.

Results:

In the 3 groups that were tested, the comparison between the mean hearing thresholds provided evidence of worsened hearing ability relative to the increase in frequency. For the tritonal mean at 500 to 2,000 Hz and 3,000 to 6,000 Hz, GIII presented the worst thresholds. For the mean of the high frequencies (9,000 and 16,000 Hz), GII presented the worst thresholds.

Conclusion:

The conventional hearing threshold evaluation did not demonstrate alterations in the 3 groups that were tested; however, the complementary tests such as high-frequency audiometry provided greater efficacy in the early detection of hearing problems, since this population's hearing loss impaired hearing ability at frequencies that are not tested by the conventional tests. Therefore, we emphasize the need of utilizing high-frequency threshold audiometry in the hearing assessment routine in combination with other audiological tests...
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Audiometria / Limiar Auditivo / Efeitos do Ruído / Odontologia / Perda Auditiva de Alta Frequência / Ruído Ocupacional Tipo de estudo: Estudo prognóstico / Estudo de rastreamento Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Int. arch. otorhinolaryngol. (Impr.) Assunto da revista: Otorrinolaringologia Ano de publicação: 2012 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Odontologia de Bauru/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Audiometria / Limiar Auditivo / Efeitos do Ruído / Odontologia / Perda Auditiva de Alta Frequência / Ruído Ocupacional Tipo de estudo: Estudo prognóstico / Estudo de rastreamento Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Int. arch. otorhinolaryngol. (Impr.) Assunto da revista: Otorrinolaringologia Ano de publicação: 2012 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Odontologia de Bauru/BR
...