Deformação do colar de implantes com junta friccional – estudo qualitativo preliminar pela Espi / Deformation of the implant collar on frictional joint implants - an Espi preliminary qualitative study
Sizo, Sérgio Rodrigues; Kanashiro, Marcus Vinícius Yamazato; Takeshita, Edson Koji; Contin, Ivo; Muramatsu, Mikiya; Soga, Diogo; Campos, Tomie Toyota de; Laganá, Dalva Cruz; Mori, Matsuyoshi.
Afiliação
  • Sizo, Sérgio Rodrigues; USP. Fousp. São Paulo. BR
  • Kanashiro, Marcus Vinícius Yamazato; USP. Fousp. São Paulo. BR
  • Takeshita, Edson Koji; USP. Fousp. São Paulo. BR
  • Contin, Ivo; USP. Fousp. São Paulo. BR
  • Muramatsu, Mikiya; USP. Fousp. São Paulo. BR
  • Soga, Diogo; USP. Fousp. São Paulo. BR
  • Campos, Tomie Toyota de; USP. Fousp. São Paulo. BR
  • Laganá, Dalva Cruz; USP. Fousp. São Paulo. BR
  • Mori, Matsuyoshi; USP. Fousp. São Paulo. BR
ImplantNews ; 9(1): 49-54, 2012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-642664
Biblioteca responsável: BR243.1
RESUMO
A região do colar cervical do implante é constantemente exposta aos esforços mastigatórios/parafuncionais, representando uma zona em potencial à ocorrência de deformações, principalmente nos implantes de conexão interna e de reduzido diâmetro. Estas sobrecargas representam um dos fatores responsáveis pela perda óssea ao redor dos implantes. O presente estudo avaliou o comportamento do colar de implantes friccionais (Kopp) de dois diâmetros (4,3 mm e 5,5 mm) sob cargas compressivas estáticas (cêntrica e excêntrica) de duas intensidades (50 N e 100 N) por meio da Interferometria Eletrônica de Padrões de Speckle (Espi – Electronic Speckle Pattern Interferometry). A técnica Espi consiste na comparação de imagens, de antes e após o carregamento, obtidas a partir da reflexão de uma fonte de luz laser incidida sobre um objeto real de superfície rugosa, resultando em um padrão de franjas. O estudo in vitro visou testar a aplicabilidade da técnica Espi para avaliar implantes e a hipótese de que quanto maior o diâmetro do implante, maior é sua resistência ao deslocamento. Foi possível obter resultados qualitativos reprodutíveis acerca da deformação ao nível do colar do implante frente aos carregamentos, validando a técnica. Franjas horizontais foram observadas nas cargas cêntricas, demonstrando o deslocamento vertical do colar do implante e franjas diagonais nas cargas excêntricas, demonstrando o deslocamento de forma oblíqua. Estes deslocamentos podem sugerir a deformação sofrida pela amostra. A técnica Espi mostrou-se viável para avaliar as deformações da região observada e a hipótese foi confirmada, visto que no implante de menor diâmetro houve maior deformação.
ABSTRACT
The collar region of osseointegrated implants is frequently exposed to masticatory/parafunctional loads, representing a potential area subjected to deformation, especially in narrow-diameter and internal connection dental implants. This study evaluated the effect of the collar of frictional implants (Kopp) at two different diameters (4.3 mm and 5.5 mm) under static compressive loads (centric and eccentric) of two magnitudes (50 and 100 N) through the Electronic Speckle Patterns Interferometry (Espi). The Espi is a technique still little used in dentistry that consists in comparing images before and after loading, obtained from the reflection of a laser light source focused on a real object surface resulting in a fringe pattern. The in vitro study aimed to test the applicability of the ESPI technique and the hypothesis that as larger is the implant diameter, as greater is the resistance to strain at level of implant collar. It was possible to obtain reproducible qualitative results about the deformation of the implant collar when subjected to loading, validating this technique. Fringes were observed horizontally in the centric loads and diagonally in eccentric loads. These results may suggest the deformation suffered by the sample. The Espi technique was feasible to assess the deformation of the region observed and the hypothesis was confirmed, since the smaller implant diameter presented greater strain.
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Estresse Mecânico / Implantes Dentários / Força Compressiva / Interferometria Tipo de estudo: Pesquisa qualitativa Idioma: Português Revista: ImplantNews Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: USP/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Estresse Mecânico / Implantes Dentários / Força Compressiva / Interferometria Tipo de estudo: Pesquisa qualitativa Idioma: Português Revista: ImplantNews Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: USP/BR
...