Dosagem correta de irradiação na polimerização da resina / Correct irradiation dose administration on resin polimerization
Fares, Nasser Hussein; Almeida, Sandro Marco Stefanini de; Vasconcelos, Alessandra; Dantas, Wania Christina Figueiredo; Missaka, Reinaldo.
Afiliação
  • Fares, Nasser Hussein; Universidade de Cuiabá. Faculdade de Odontologia. Cuiabá. BR
  • Almeida, Sandro Marco Stefanini de; Universidade de Cuiabá. Faculdade de Odontologia. Cuiabá. BR
  • Vasconcelos, Alessandra; Universidade de Cuiabá. Faculdade de Odontologia. Cuiabá. BR
  • Dantas, Wania Christina Figueiredo; s.af
  • Missaka, Reinaldo; s.af
Full dent. sci ; 1(3): 299-304, abr.-jun. 2010. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-642954
Biblioteca responsável: BR1264.1
RESUMO
Muitas pesquisas têm revelado associação à intensidade de luz dos aparelhos fotoativadores, porém relação direta da dureza está mais relacionada à energia absorvida do que o método de fotoativação. Amostras da resina composta Filtek Z250, (A3) foram polimerizadas com LED macrodiodo marca “Blue Star 1” (Microdont) uma intensidade de 1.000mW/cm2 e um convencional de luz halógena marca VIP Curing Ligth ( Bisco Inc. USA) e intensidade de 600mW/cm2. A irradiação foi realizada em cinco tempos variáveis de exposição 10s, 15s e 20s, 30s. Foram realizados 5 corpos-de-prova para cada energia de polimerização empregada, totalizando 50 espécimes. Os testes de dureza Knoop foram realizados após o período de armazenagem por 24 h, nas regiões de superfície Topo e Base, sob uma carga de 100 gramas durante 10 segundos, e através de um microdurômetro (Durimet - Leitz-Welzlar) penetrador tipo Knoop, a amostra foi submetida a 6 penetrações sendo 3 na superfície de incidência de luz (topo) e 3 na região oposta, totalizando 300 medições. Os valores de dureza Knoop no topo foram mais elevados com a aplicação da luz do LED BlueStar e crescente em relação com o aumento do tempo de aplicação.). A significância desses resultados revela que a intensidade da luz está diretamente relacionada com o tempo de exposição para proporcionar a quantidade de irradiação correta recomendada em um total de 15.000mW/cm2 ou 15J/ cm2.
ABSTRACT
Many surveys have revealed an association to the light intensity from photopolymerizationdevices; however hardness is more related to the absorbed energy than the photopolymerization method. Filtek Z250 composite resin samples were polymerized with a macro-diode LED, “Blue Star 1” (Microdont), with a light intensity of 1,000mW/cm² and with a conventional light curing, branded VIP Curing Light (Bisco Inc. USA) with an intensity of 600mW/cm². An irradiation (exposition) was performed in five different exposition times 10s, 15s and 20s, 30s. There were performed 5 body-tests for each polymerization energy exposition, summing 50 samples. Knoop hardness tests were performed after 24 hours storing period, at surfaces areas “Top and Base”, under a 100gr load during 10 seconds, with a hardness micro-calibrator (Durimet – Leitz-Welzlar) and Knoop deepness (penetration power); the samples were exposed to 6 penetrations, with 3 light incidences at top surface and 3 at the opposite area, summing 300 measures. Knoophardness values at the top with LED Blue Star light exposition were the highest, and with increasing hardness in relation to time exposition. The significance of these results reveals that light intensity is directly related with time exposition in order to provide a correct irradiation quantity recommended with a total of 15,000mW/cm² or 15J/cm².
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Tecnologia Odontológica / Resinas Compostas / Materiais Dentários / Microscopia de Polarização Idioma: Português Revista: Full dent. sci Assunto da revista: Odontologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de Cuiabá/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Tecnologia Odontológica / Resinas Compostas / Materiais Dentários / Microscopia de Polarização Idioma: Português Revista: Full dent. sci Assunto da revista: Odontologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de Cuiabá/BR
...