Comparison of the reliability of multifocal visual evoked cortical potentials generated by pattern reversal and pattern pulse stimulation
Souza, G.S.; Schakelford, H.B.; Moura, A.L.A.; Gomes, B.D.; Ventura, D.F.; Fitzgerald, M.E.C.; Silveira, L.C.L..
Afiliação
  • Souza, G.S.; Universidade Federal do Pará. Núcleo de Medicina Tropical. Belém. BR
  • Schakelford, H.B.; Christian Brothers University. Memphis. US
  • Moura, A.L.A.; Universidade de São Paulo. Instituto de Psicologia. São Paulo. BR
  • Gomes, B.D.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
  • Ventura, D.F.; Universidade de São Paulo. Instituto de Psicologia. São Paulo. BR
  • Fitzgerald, M.E.C.; Christian Brothers University. Memphis. US
  • Silveira, L.C.L.; Universidade Federal do Pará. Núcleo de Medicina Tropical. Belém. BR
Braz. j. med. biol. res ; 45(10): 955-961, Oct. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-647757
Biblioteca responsável: BR1.1
ABSTRACT
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Reconhecimento Visual de Modelos / Estimulação Luminosa / Potenciais Evocados Visuais Tipo de estudo: Estudo prognóstico Limite: Adulto / Humanos Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil / Estados Unidos Instituição/País de afiliação: Christian Brothers University/US / Universidade Federal do Pará/BR / Universidade de São Paulo/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Reconhecimento Visual de Modelos / Estimulação Luminosa / Potenciais Evocados Visuais Tipo de estudo: Estudo prognóstico Limite: Adulto / Humanos Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil / Estados Unidos Instituição/País de afiliação: Christian Brothers University/US / Universidade Federal do Pará/BR / Universidade de São Paulo/BR
...