Your browser doesn't support javascript.
loading
Adesão de células do ligamento periodontal de ratos a diferentes superfícies de titânio: estudo comparativo in vitro / Adhesion of ligament periodontal cells to different titanium surfaces: an in vitro comparative study
Alves, Luciana Bastos; Ginani, Fernanda; Silva, José Sandro Pereira da; Alves-Júnior, Clodomiro; Barboza, Carlos Augusto Galvão.
Afiliação
  • Alves, Luciana Bastos; Universidade Federal do Rio Grande do Norte. Programa de Pós-graduação em Odontologia. Natal. BR
  • Ginani, Fernanda; Universidade Federal do Rio Grande do Norte. Natal. BR
  • Silva, José Sandro Pereira da; Universidade Federal do Rio Grande do Norte. Departamento de Odontologia. Natal. BR
  • Alves-Júnior, Clodomiro; Universidade Federal do Rio Grande do Norte. Departamento de Engenharia Mecânica. Natal. BR
  • Barboza, Carlos Augusto Galvão; Universidade Federal do Rio Grande do Norte. Departamento de Morfologia. Natal. BR
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-663261
Biblioteca responsável: BR1.1
RESUMO

Objetivo:

o presente estudo teve como objetivo avaliar, através de experimentos in vitro utilizando cultura celular, a capacidade de adesão das células do ligamento periodontal de ratos sobre as superfícies de titânio polidas e tratadas por nitretação iônica (plasma).

Método:

foram utilizados discos de titânio grau II ASTM F86 nas dimensões de 15mm de diâmetro por 1,5mm de espessura, os quais receberam diferentes tratamentos de superfície em 2 grupos distintos polido e nitretado a plasma por gaiola catódica. As células foram isoladas do ligamento periodontal de ratos e cultivadas em meio de cultura alfa-MEM contendo antibióticos e suplementado com 10% de FBS, por 72 horas, em atmosfera úmida com 5% de CO2 a 37ºC. No subcultivo as células foram cultivadas sobre os discos de titânio em uma placa de 24 poços, na densidade de 1 x 104 células por poço, incluindo-se controles positivos sem os discos de titânio. Após 24 horas de cultivo, as células foram submetidas à contagem em câmara de Neubauer.

Resultados:

os resultados mostraram que a média de adesão celular foi maior na superfície controle (0,62±0,22) do que nos grupos polido (0,46±0,14) e nitretado (0,33±0,10). Foi observada diferença estatisticamente significante entre os grupos controle e nitretado (p=0,04), porém não se observou diferença na adesão celular entre os grupos polido e nitretado.

Conclusão:

a capacidade de adesão das células do ligamento periodontal de rato a superfícies de titânio não sofreu influência do tratamento de superfície dado ao material.
ABSTRACT

Objective:

the present study aims to evaluate, through experiments in vitro, the adhesion capacity of rats periodontal ligament cells on polishing and treated by ionic nitriding (plasma) titanium surfaces.

Method:

degree II titanium discs (ASTM F86), 15mm of diameter for 1,5mm of thickness, which had received different treatments from surface in 2 distinct groups (polished and cathodic cage plasma nitriding) were used. The cells were isolated from periodontal ligament of rats and cultivated in alpha-MEM contend antibiotic and supplemented with 10% of FBS, for 72 hours, in humid atmosphere with 5% of CO2 at 37ºC. In the subculture the cells were cultivated on titanium discs in 24-well cell culture plates, with a density of 1 x 104 cells per well, including wells with no discs (control). After 24 hours of cultivation, the cells were counted in a Neubauer chamber.

Results:

the results had shown that the mean adhesion was greater on the control surface (0.62±0.22) than on polished (0.46±0.14) and nitriding (0.33±0.10) surfaces. Statistical significant difference was observed between the groups control and cathodic cage plasma nitriding (p=0.04), nevertheless no diference was found between polished and nitriding groups.

Conclusion:

the adhesion capacity of rat periodontal ligament cells on the titanium surfaces was not influenced by the different surface treatments given to the material, since none of these contributed positively in the process of cellular adhesion.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Ligamento Periodontal / Titânio / Adesão Celular Limite: Animais País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio Grande do Norte/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Ligamento Periodontal / Titânio / Adesão Celular Limite: Animais País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio Grande do Norte/BR
...