Your browser doesn't support javascript.
loading
Contaminação por mercúrio na Odontologia: a utilidade da análise quantitativa em ambiente de prática restauradora com amálgama / Mercury contamination in Dentistry: the utility of quantitative analysis in environment with amalgam restorative practice
Campos, Riva Marques; Lacerda, Raimundo Alexandre da Silveira Vidigal; Fraga, Ricardo Carvalhaes; Hayassy, Armando; Rodrigues Filho, Hélio Sampaio; Câmara, Volney de Magalhães.
Afiliação
  • Campos, Riva Marques; Faculdades São José. Faculdade de Odontologia. Rio de Janeiro. BR
  • Lacerda, Raimundo Alexandre da Silveira Vidigal; Faculdades São José. Faculdade de Odontologia. Rio de Janeiro. BR
  • Fraga, Ricardo Carvalhaes; Universidade Federal Fluminense. Faculdade de Odontologia. Niterói. BR
  • Hayassy, Armando; Faculdades São José. Faculdade de Odontologia. Rio de Janeiro. BR
  • Rodrigues Filho, Hélio Sampaio; Universidade do Estado do Rio de Janeiro. Faculdade de Odontologia. Rio de Janeiro. BR
  • Câmara, Volney de Magalhães; Universidade Federal do Rio de Janeiro. Instituto de Estudos em Saúde Coletiva. Rio de Janeiro. BR
J. Health Sci. Inst ; 30(3)jul.-set. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-670562
Biblioteca responsável: BR12.1
RESUMO
Objetivo - Verificar o uso e aplicação de um medidor portátil de análise quantitativa de vapores de mercúrio. Os locais de escolha foram a Clínica Odontológica e o Laboratório Multidisciplinar 104 da Faculdade de Odontologia das Faculdades São José, Rio de Janeiro-RJ, Brasil. Nesses locais ocorrem muitas atividades restauradoras com amálgama dentário realizadas por alunos, tornando-se importante a verificação da possível contaminação por vapores tóxicos de mercúrio existente naqueles ambientes. Métodos - Para a medição foi utilizado um aparelho analisador Zeeman quantitativo avançado de mercúrio portátil da marca Lumex modelo RA-915+. O aparelho foi acionado no final da tubulação de rejeito das cuspideiras das cadeiras A, C, D, E, F, J, H e ar do amalgamador recém-acionado. No Laboratório Multidisciplinar 104 foram inspecionados ar/ambiente e em manequim usado para treino. Foram feitas também inspeções no ar em ambiente onde não se usa amálgama a fim de verificação do teor zero. Resultados - Na Clínica Odontológica as cadeiras C, E, F e H foram as que apresentaram os maiores índices de contaminação, dentre estas a cadeira H destacou-se com 26.140 ngHg/m³. Os locais onde não se manipula amálgama o índice foi 0ngHg/m³. Conclusões - Os altos índices de vapores de mercúrio nas tubulações das cadeiras indicam que as medidas seguras de descartes de resíduos não estão sendo realizadas adequadamente. Este sistema de medição quantitativa direta mostrou-se simples no manuseio e extremamente útil no monitoramento de ambientes sujeitos à contaminação por vapores tóxicos de mercúrio.
ABSTRACT
Objective - To examine the use and application of a portable meter for quantitative analysis of mercury vapors. The places of choice were the Dental Clinic and Laboratory Training 104 of the School of Dentistry of São José College, Rio de Janeiro-RJ, Brazil. In these places many activities occur restorative dental amalgam made by students, making it important to check the possible contamination by toxics vapors mercury existing in those environments. Methods - For the measurement we used an advanced device analyzer Zeeman quantitative mercury brand laptop Lumex model RA-915+. The device was fired at the end of the waste pipe spitting chairs A, C, D, E, F, J, H and air amalgamator newly activated. In the Laboratory Training 104 were inspected air/environment and dummy used for training. Inspections were performed also on air at ambient where amalgam is not used to check content zero. Results - In Dental Clinic chairs C, E, F and H were the ones that showed the highest levels of contamination, among these the seat H stood out with 26.140 ngHg / m³. Places where no handles amalgam index was 0ngHg/m³. Conclusions - The high levels of mercury vapor in the pipes of the chairs indicate that measures of safe waste disposal are not being carried out properly. This direct quantitative measurement system proved simple in handling and extremely useful in monitoring environments subject to contamination by toxic mercury vapors.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Amálgama Dentário / Estudos de Avaliação como Assunto Tipo de estudo: Ensaio clínico controlado / Estudo diagnóstico / Estudo de avaliação Idioma: Português Revista: J. Health Sci. Inst Assunto da revista: Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdades São José/BR / Universidade Federal Fluminense/BR / Universidade Federal do Rio de Janeiro/BR / Universidade do Estado do Rio de Janeiro/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Amálgama Dentário / Estudos de Avaliação como Assunto Tipo de estudo: Ensaio clínico controlado / Estudo diagnóstico / Estudo de avaliação Idioma: Português Revista: J. Health Sci. Inst Assunto da revista: Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdades São José/BR / Universidade Federal Fluminense/BR / Universidade Federal do Rio de Janeiro/BR / Universidade do Estado do Rio de Janeiro/BR
...