Your browser doesn't support javascript.
loading
Evaluación del nivel de contaminación por la micotoxina "Ocratoxina" en muestras de Capsidum Annum "Paprika" usando los métodos ELISA y Cromatografía líquida de alta perfomancia "HPLC" / Evaluation of the level of contamination by the
Rojas-Jaimes, Jesús.
Afiliação
  • Rojas-Jaimes, Jesús; Efada Export. Laboratorio de Micrcobiología y Micotoxina. Lima. PE
Horiz. méd. (Impresa) ; 8(2): 48-52, dic. 2008. tab, graf
Artigo em Espanhol | LILACS, LIPECS | ID: lil-677730
Biblioteca responsável: PE1.1
RESUMEN

Objetivo:

Las micotoxinas son un problema de salud pública a nivel mundial, como ejemplo las aflatoxinas y las ocratoxinas son carcinogénicas y tóxicas respectivamente a nivel de partes por billon "ppb", la comunidad europea ha impuesto límites permisibles para la concentración de ocratoxina presente en alimentos, el objetivo del presente trabajo es evaluar la confiabilidad de una prueba barata y eficaz "ELISA" en la medición de la ocratoxina en Capsicun annuum. Material y

Método:

En este trabajo se evaluó el parámetro principal de confibilidad del ELISA Veratox Neogen y el ELISA kit R-Biopharm utilizando la T de Student y los índices de correlación entre los ELISA y el método referencial HPLC.

Resultados:

El resultado de la T de Student fue t0,05(2)(18)=0,86tabla=2,101 y los coeficientes de correlación entre los ELISAS y el HPL fueron 0.91 y 0.8 para el kit Veratox Neogen y el kit Biopharm.

Conclusión:

La mejor correlación del ELISA respecto al método referencial HPLC fue usando el kit "Veratox" Neogen con un valor de 0.91.
ABSTRACT

Objective:

Mycotoxins are important in public health, especially aflatoxin and ochratoxin because they are very toxic at the level of parts per billion "ppb". The objective of this study is to evaluate an inexpensive and reliabe method, "ELISA" to measure the level of ochratoxin and compare it with the referencial method "High Performance Liquid Chromatography-HPLC". Material and

Methods:

We evaluated the data showed by the ELISA method using the Veratox and R- Biopharm Kits and HPLC using the Student's t-test and the coefficients of correlation between ELISA and HPLC.

Results:

The Student's t-test was t0, 05 (2) (18) = 0.86 table = 2.101 the coefficients of correlation between the ELISA and HPL were 0.91 and 0.8 using the Veratox Neogen and R-Biopharm kits respectively.

Conclusion:

The best coeffient of correlation between the referencial method HPLC and ELISA was 0.91 using the Veratox "Neogen kit.
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Ensaio de Imunoadsorção Enzimática / Micotoxicose / Cromatografia Líquida de Alta Pressão / Aflatoxinas / Micotoxinas / Ocratoxinas Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Horiz. méd. (Impresa) Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Efada Export/PE
Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Ensaio de Imunoadsorção Enzimática / Micotoxicose / Cromatografia Líquida de Alta Pressão / Aflatoxinas / Micotoxinas / Ocratoxinas Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Horiz. méd. (Impresa) Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Efada Export/PE
...