Your browser doesn't support javascript.
loading
Glutaraldeído: avaliação das condições sanitárias da solução em uso para o reprocessamento de endoscópios / Glutaraldehyde: evaluation of sanitary conditions of the solution in use for reprocessing of endoscopes / Glutaraldehído: evaluación de las condiciones sanitarias de la solución en uso para el reprocesamiento de endoscopios
Pires, Francine Vieira; Tipple, Anaclara Ferreira Veiga; Barbosa, Jackeline Maciel; Souza, Adenicia Custódia Silva e; Ribeiro, Luana Cássia Miranda; Neves, Heliny Carneiro Cunha.
Afiliação
  • Pires, Francine Vieira; Universidade Federal de Goiás. Hospital das Clínicas. Goiás. BR
  • Tipple, Anaclara Ferreira Veiga; Universidade Federal de Goiás. Faculdade de Enfermagem. Goiás. BR
  • Barbosa, Jackeline Maciel; Secretaria Municipal de Saúde. Goiania. BR
  • Souza, Adenicia Custódia Silva e; Universidade Federal de Goiás. Faculdade de Enfermagem. BR
  • Ribeiro, Luana Cássia Miranda; Universidade Federal de Goiás. Faculdade de Enfermagem. BR
  • Neves, Heliny Carneiro Cunha; Universidade Federal de Goiás. Faculdade de Enfermagem. BR
Rev. enferm. UERJ ; 20(4): 470-475, out.-dez. 2012. tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: lil-688950
Biblioteca responsável: BR1366.1
RESUMO
Estudo transversal, descritivo, realizado em 20 serviços de endoscopia digestiva alta da cidade de Goiânia-GO, em 2007, cujo objetivo foi avaliar as condições do glutaraldeído em uso para o reprocessamento de endoscópios. Os dados foram obtidos por meio de um roteiro sobre as condições sanitárias, pela aferição do pH e concentração do glutaraldeído em uso. A maioria dos serviços não realizava o controle de concentração e pH do glutaraldeído e, quando aferidos pelos pesquisadores, metade estava de acordo com as recomendações para um dos parâmetros e apenas 3(15%) estavam adequados simultaneamente. Quanto aos rótulos, foram encontrados 7(35%) no frasco de ativação do produto e 13(65%) no recipiente do produto em uso. Em 17(85%) serviços, o glutaraldeído era inadequadamente desprezado diretamente na pia. Os parâmetros de qualidade do reprocessamento químico utilizando o glutaraldeído para a desinfecção de alto nível em endoscópios, nos serviços investigados, podem representar risco para os usuários.
ABSTRACT
Cross sectional, descriptive study, conducted in 20 services of High Digestive Endoscopy in the city of Goiânia, GO, Brazil, in 2007, whose objective was to evaluate the conditions of glutaraldehyde in use for reprocessing of endoscopes. Datawere collected through a script about sanitary conditions, by pH assessment, and concentration of glutaraldehyde in use. Most services performed neither concentration control nor pH of glutaraldehyde. When assessed by researchers, half of them follow recommendations to only one of the parameters, and only 3(15%) were adequate simultaneously. As for labels, there were 7(35%) in the bottle of activation of the product and 13(65%) in the container of the product in use. In 17(85%) services, the glutaraldehyde was discarded directly and inadequately into the sink. Quality parameters of chemical reprocessing using glutaraldehyde for highlevel disinfection of endoscopes, in the investigated services can bring risk to users.
RESUMEN
Estudio transversal, descriptivo, realizado en 20 servicios de endoscopia digestiva alta en la ciudad de Goiânia-GO-Brasil, en 2007, cuyo objetivo fue evaluar las condiciones del glutaraldehído en uso para el reprocesamiento de endoscopios. Los datos fueron recolectados a través de un guión sobre las condiciones sanitarias, por la aferición del pH y concentración del glutaraldehído en uso. La mayoría de los servicios no realizaba el control de concentración y pH del glutaraldehído y, cuando aferidos por los investigadores, la mitad se encontraba de acuerdo con recomendaciones para uno de los parámetros y solo 3(15%) estaban adecuados simultáneamente. Cuanto a los rótulos, fueron encontrados 7(35%) en el frasco de activación delproducto y 13(65%) en el recipiente del producto en uso. En 17(85%) servicios, el glutaraldehído era descartado directamente en el fregadero. Los parámetros de calidad del reprocesamiento químico utilizando el glutaraldehído para la desinfección de alto nivel en endoscopios, en los servicios investigados, pueden representar peligro para los usuarios.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BDENF - Enfermagem / LILACS Assunto principal: Controle de Qualidade / Enfermagem / Glutaral / Endoscopia / Toxicidade Tipo de estudo: Estudo observacional / Estudo de prevalência Limite: Humanos Idioma: Português Revista: Rev. enferm. UERJ Assunto da revista: Cuidados de Enfermagem / Enfermagem / Sa£de P£blica Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Secretaria Municipal de Saúde/BR / Universidade Federal de Goiás/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BDENF - Enfermagem / LILACS Assunto principal: Controle de Qualidade / Enfermagem / Glutaral / Endoscopia / Toxicidade Tipo de estudo: Estudo observacional / Estudo de prevalência Limite: Humanos Idioma: Português Revista: Rev. enferm. UERJ Assunto da revista: Cuidados de Enfermagem / Enfermagem / Sa£de P£blica Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Secretaria Municipal de Saúde/BR / Universidade Federal de Goiás/BR
...