Comparação entre o laser de baixa potência, ultrassom terapêutico e associação, na dor articular em ratos Wistar / Comparison of low level laser, ultrasonic therapy and association in joint pain in Wistar rats
Coradini, Josineia Gresele; Mattjie, Thiago Fernando; Bernardino, Giovanni Ribeiro; Peretti, Ana Luiza; Kakihata, Camila Mayumi Martin; Errero, Tatiane Kamada; Escher, Assis Roberto; Bertolini, Gladson Ricardo Flor.
Afiliação
  • Coradini, Josineia Gresele; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Mattjie, Thiago Fernando; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Bernardino, Giovanni Ribeiro; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Peretti, Ana Luiza; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Kakihata, Camila Mayumi Martin; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Errero, Tatiane Kamada; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Escher, Assis Roberto; Universidade Estadual do Oeste do Parana. Cascavel. BR
  • Bertolini, Gladson Ricardo Flor; Universidade Estadual do Oeste do Parana. Cascavel. BR
Rev. bras. reumatol ; 54(1): 7-12, Jan-Feb/2014. graf
Artigo em Português | LILACS | ID: lil-704280
Biblioteca responsável: BR1.1
RESUMO

Introdução:

Tanto o ultrassom terapêutico quanto o laser de baixa potência são utilizados para o controle da dor musculoesquelética, apesar de controvérsias. Ainda, a literatura é pobre e também apresenta resultados controversos sobre efeitos cumulativos da associação de técnicas. Assim, o objetivo foi comparar os efeitos antinociceptivos do laser, do ultrassom e da associação destes.

Métodos:

Foram utilizadas 24 ratas, divididas em GPL - indução de hiperestesia no joelho direito, e não tratadas; GUS - ultrassom terapêutico (1 MHz, 0,4 W/cm2); GL - laser de baixa potência (830 nm, 8 J/cm2); GL+US - tratadas com as duas técnicas. Para a hiperestesia foram injetados no espaço tíbio-femoral 100 μl de solução de formalina 5%, e avaliada por filamento de von Frey digital, antes (AV1), 15 (AV2), 30 (AV3) e 60 (AV4) minutos após a indução.

Resultados:

Na comparação dentro dos grupos, para o limiar de retirada quando o filamento foi aplicado nos joelhos, foi possível observar volta aos valores basais apenas para GUS. Nas comparações entre os grupos houve diferenças em AV3, sendo que GL foi maior do que PL. Em AV4 os três grupos tratados apresentaram valores maiores que o placebo. No limiar de retirada na superfície plantar GL mostrou retorno dos valores basais em AV3, e GUS e GL+US retornaram em AV4. Na comparação entre os grupos, em AV3 havia um limiar menor em GPL ao comparar com GL e GUS (p<0,05), e em AV4 só havia diferenças ao comparar GPL com GUS.

Conclusão:

Ambas as modalidades apresentaram efeitos antinociceptivos. .
ABSTRACT

Introduction:

Both therapeutic ultrasound as a low level laser therapy are used to control musculoskeletal pain, despite controversy about its effects, yet the literature is poor and also presents conflicting results on possible cumulative effects of techniques association. The aim was to compare the antinociceptive effects of low level laser therapy, therapeutic ultrasound and the association.

Methods:

24 Wistar rats were divided into GPL - induction of hyperesthesia in the right knee, and untreated; GUS - treated with therapeutic ultrasound (1 MHz, 0.4 W / cm2) GL - low intensity laser (830 nm, 8 J/cm2); GL+US - treated with both techniques. To produce the hyperesthesia 100 μl of 5% formalin solution were injected into the tibiofemoral joint space, which was assessed by von Frey filament digital before (EV1), 15 (EV2), 30 (EV3) and 60 (EV4) minutes after induction.

Results:

In comparison within groups, for the withdrawal threshold when the fi lament was applied to the knee, the back to baseline was observed only for GUS. Comparisons between groups were not different in EV3, and GL was higher than GPL. In EV4 the three groups effectively treated were higher than placebo. On withdrawal threshold on the plantar surface, GL showed return to baseline values already in EV3, and GUS and GL+US returned in EV4. Comparing the groups in EV3 there was a significantly lower threshold to compare GPL with GL and GUS (p <0.05), and there was only EV4 differences when comparing GPL with GUS.

Conclusion:

Both modalities showed antinociceptive effects. .
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Terapia por Ultrassom / Artralgia / Terapia com Luz de Baixa Intensidade / Articulação do Joelho Tipo de estudo: Fatores de risco Limite: Animais Idioma: Português Revista: Rev. bras. reumatol Assunto da revista: Reumatologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual do Oeste do Parana/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Terapia por Ultrassom / Artralgia / Terapia com Luz de Baixa Intensidade / Articulação do Joelho Tipo de estudo: Fatores de risco Limite: Animais Idioma: Português Revista: Rev. bras. reumatol Assunto da revista: Reumatologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual do Oeste do Parana/BR
...