Your browser doesn't support javascript.
loading
Avaliação da liberação de íon fluoreto de cimentos ionoméricos antes e após a recarga e com proteção da superfície / Fluoride ion release from glass ionomer cements before and after recharge and surface protection
Antunes, Débora Pinto; Antunes, Drusila Pinto; Matos, Renato Camargo; Kamozaki, Maria Beatriz Beber; Pagani, Clovis; Salgado, Ivone Oliveira.
Afiliação
  • Antunes, Débora Pinto; s.af
  • Antunes, Drusila Pinto; s.af
  • Matos, Renato Camargo; Universidade Federal de Juiz de Fora. Juiz de Fora. BR
  • Kamozaki, Maria Beatriz Beber; s.af
  • Pagani, Clovis; Universidade Estadual Júlio de Mesquita Filho. São José dos Campos. BR
  • Salgado, Ivone Oliveira; Universidade Federal de Juiz de Fora. Juiz de Fora. BR
Artigo em Português | LILACS | ID: lil-724209
Biblioteca responsável: BR1264.1
RESUMO

Objetivo:

Avaliar a liberação de íon fluoreto de 2 cimentos de ionômerode vidro (CIV) anidro e 2 modificados por resina composta antes e apósrecarga com fluoreto de sódio neutro a 2% por 4min. e após a proteçãoda superfície do CIV Maxxion R com um adesivo odontológico, umverniz cavitário e um esmalte incolor para unhas.

Métodos:

Com uma matriz de aço inox com 2mm x 6mm,confeccionou-se 5 corpos de prova de cada material, que foramimersos em 5mL de água deionizada, trocada a cada 24h. Foramrealizadas leituras em um potenciômetro nos dias 1, 2, 9 e 17 na 1ª e 2ªetapas, e as amostras foram tamponadas com solução TISAB III. Na 2ªetapa, as amostras foram submetidas à recarga e novamente imersasem 5mL de água deionizada. Na 3ª etapa foi realizada a proteção dasuperfície dos CIVs e feitas leituras nos 5min., 24h, 48h e 72h. Utilizouseos testes estatísticos Post Hoc de Tukey e t Student (p<0,05).

Resultados:

Observou-se diferença estatisticamente significante aocomparar a 1ª com a 2ª etapas em todos os materiais, exceto no dia 2para o Vidrion R e para o VitroFil LC. Na 3ª etapa observou-se que emtodos os materiais, comparando os primeiros 5 min. com os outrostempos, as diferenças entre as médias da liberação das concentraçõesde íon fluoreto foram estatisticamente significantes. Ao 0comparar osdemais tempos, tanto o verniz quanto o esmalte incolor para unhasapresentou diferença estatisticamente significante entre 24h e 48h,bem como em 24h e 72h.

Conclusão:

Os CIVs anidros tiveram maior efetividade na liberação deíon fluoreto e na recarga em comparação com os CIVs modificados porresina composta e o Maxxion R apresentou um comportamentohomogêneo e estatisticamente significante nas duas etapas. Todos osmateriais protetores testados foram eficazes, e o esmalte incolor paraunhas apresentou o melhor comportamento...
ABSTRACT

Objective:

To evaluate fluoride ion release from two anhydrous glassionomer cements (GICs) and two resin-modified GICs (RMGICs) before and after recharge with 2% neutral sodium fluoride for 4 min and after surface protection of the Maxxion R GIC with an adhesive system, a cavity varnish and a colorless nail polish.

Method:

A stainless steel 2x6 mm matrix was used for fabricating 5 specimens of each material, which were immersed in 5 mL of deionized water, renewed every 24 h. Measurements with a potentiometer were performed on days 1, 2, 9 and 17, in the 1st and 2nd phases, and thespecimens were buffered with a TISAB III solution. In the 2nd phase, thespecimens were subjected to recharge and immersed again in 5 mL ofdeionized water. In the 3rd phase, the GIC surfaces were protected andreadings were made at 5 min, 24 h, 48 h and 72 h. TukeyÆs post-hoc and StudentÆs t tests were used for statistical analyses (p<0.05).

Results:

There was statistically significant difference in the comparison between the 1st and 2nd phases for all materials, except at day 2 for Vidrion R and VitroFil LC. In the 3rd phase, it was observed that for all materials, comparison of the first 5 min with the other times revealedstatistically significant differences among the means of fluoride ionrelease. In the comparison with the other times, both the varnish and the colorless nail polish presented statistically significant differencebetween 24 and 48 h as well as between 24 and 72 h.

Conclusion:

The anhydrous GICs were more effective in fluoride ion release and recharge compared with the RMGICs. Maxxion R presented a homogeneous and statistically significant behavior in both phases. All materials for surface protection were efficient and the colorless nail polish had the best behavior...
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Potenciometria / Resinas Compostas / Materiais Dentários / Fluoretos / Cimentos de Ionômeros de Vidro Limite: Humanos Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual Júlio de Mesquita Filho/BR / Universidade Federal de Juiz de Fora/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Potenciometria / Resinas Compostas / Materiais Dentários / Fluoretos / Cimentos de Ionômeros de Vidro Limite: Humanos Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual Júlio de Mesquita Filho/BR / Universidade Federal de Juiz de Fora/BR
...