Your browser doesn't support javascript.
loading
Estudo in vitro da resistência ao cisalhamento dos compósitos Concise Ortodôntico e Ortho-One / “In vitro” study of shear bond strength of the composite concise orthodontic and Ortho-One
Coelho, Ulisses; Meister, Edson do Rocio; Hilgenberg, Sérgio Paulo; Germiniani, Wagner Izumi Sawada.
Afiliação
  • Coelho, Ulisses; UEPG. BR
  • Meister, Edson do Rocio; UEPG. BR
  • Hilgenberg, Sérgio Paulo; UEPG. BR
  • Germiniani, Wagner Izumi Sawada; UEPG. BR
Ortho Sci., Orthod. sci. pract ; 5(20): 499-504, 2012. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-729315
Biblioteca responsável: BR243.1
RESUMO
Este estudo avaliou a resistência adesiva ao cisalhamento (RAC) e o índice de adesivo remanescente (IAR) na colagem de bráquetes metálicos com as resinas Concise Ortodôntico / 3M e Ortho-One / Bisco. Foram construídos corpos de prova com 60 pré-molares humanos superiores divididos aleatoriamente (n=30) para cada um dos grupos. O procedimento de colagem foi realizado conforme as instruções de cada fabricante. O ensaio de cisalhamento foi realizado com uma máquina MTS 810. Os resultados mostraram uma média de RAC para as resinas Concise e Ortho-One de 29,99±15,89 MPa e de 22,52±12,2 MPa, respectivamente. A análise estatística pelo teste t de Student não mostrou diferença estatística significante quanto à RAC (p>0,05). Para avaliação do IAR, foi utilizado o teste não paramétrico de Kruskal-Wallis, o qual não mostrou diferença estatística significativa quanto ao padrão de descolagem (p=0,361). Conclui-se que não há diferença significativa entre as resinas testadas e ambos os materiais apresentaram padrões aceitáveis para um bom desempenho clínico.
ABSTRACT
This study assessed the shear bond strength and adhesive remanescent index (ARI) when bonding metallic brackets using the composites Concise Orthodontic Bonding System/3M and Ortho One/Bisco. Sixty human upper premolars were used divided randomly in two groups. Bonding procedure was conducted following each manufacturer’s instructions. The results showed that the mean shear bond strength with Concise and Ortho One ranged between 29,99 ± 15,89 MPa and 22,52 ± 12,2 MPa, respectively. Data were submitted to statistical analysis by the t test of Student (showed no significant statistical differences between the composites) (p>0,05). In evaluation of ARI was utilized Kruskal-Wallis test without difference statistical significance. Both the materials showed acceptable patterns for a good clinical performance.
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Colagem Dentária / Braquetes Ortodônticos / Resistência ao Cisalhamento Tipo de estudo: Ensaio clínico controlado Limite: Adolescente / Humanos Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UEPG/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Colagem Dentária / Braquetes Ortodônticos / Resistência ao Cisalhamento Tipo de estudo: Ensaio clínico controlado Limite: Adolescente / Humanos Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UEPG/BR
...