Your browser doesn't support javascript.
loading
Adaptação marginal em copings de dois sistemas cerâmicos livres de metal / Marginal fit in copings of two metal free ceramic systems
Kapczinski, Myriam Pereira; Sanada, Jefferson Tomio; Souza Junior, Oswaldo Baptista de; D'Arrigo, Luis Fernando.
Afiliação
  • Kapczinski, Myriam Pereira; Universidade Federal do Rio Grande do Sul. Porto Alegre. BR
  • Sanada, Jefferson Tomio; Universidade Federal do Rio Grande do Sul. Porto Alegre. BR
  • Souza Junior, Oswaldo Baptista de; Universidade Federal do Rio Grande do Sul. Porto Alegre. BR
  • D'Arrigo, Luis Fernando; s.af
Full dent. sci ; 5(20): 584-589, jul.-set. 2014. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-737447
Biblioteca responsável: BR1264.1
RESUMO
Este trabalhou avaliou a adaptação marginal de infraestruturas cerâmicas (copings em alumina) de dois sistemas cerâmicos livres de metal. Foram pesquisados os sistemas In-Ceram e Procera. Os valores de discrepância vertical presentes entre as margens de nove copings de cada sistema cerâmico e a margem de um modelo mestre metálico foram medidos com microscópio eletrônico de varredura em 5 pontos de cada infraestrutura. Esses valores foram medidos em micrômetros (pm). Os resultados foram analisados estatisticamente com o software SPSS (Statistical Package for the Social Sciences 11.0), através do teste t de Student, considerando-se significativos os valores de p<0(05. Os valores médios de discrepância marginal dos dois sistemas, medidos em microscópio eletrônico de varredura, mostraram diferença estatística entre si (p=0,001), sendo observadas desadaptações de 39±11pm (sistemas Procera) e 11 5±56pm (sistema In-Ceram). Conclui-se que os dois sistemas cerâmicos livres de metal avaliados apresentaram adaptação marginal dentro de limites aceitáveis clinicamente.
ABSTRACT
This work has evaluated the marginal fit of alumina copings of two metal free ceramic systems, namely Procera and In-Ceram systems. The marginal fit values of the margins in nine copings of each ceramic system and in a metal master model were assessed using electron- scanning microcopy in five points of the margin of each coping. Such values were measured in micrometers (pm). The results were analyzed statistically by the SPSS software (p<0.05). The marginal fit mean values for both systems have presented statistical difference (p=0.001), being of 39±11 pm and 115±56pm for the Procera and Inc-Ceram systems, respectively. Both systems have presented marginal fit according to the clinical acceptance.
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Cerâmica / Adaptação Marginal Dentária / Materiais Dentários / Óxido de Alumínio Idioma: Português Revista: Full dent. sci Assunto da revista: Odontologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio Grande do Sul/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Cerâmica / Adaptação Marginal Dentária / Materiais Dentários / Óxido de Alumínio Idioma: Português Revista: Full dent. sci Assunto da revista: Odontologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio Grande do Sul/BR
...